ArticleBMC oral health2024
Finite element analysis of stress distribution on residual root structure in socket shield procedure following immediate dental implant placement: an in vitro study.
Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 9 citations in OpenAlex.
- Optimizing Alveolar Ridge Preservation and GBR: A Systematic Review of Membranes, Grafts, and Soft Tissue Strategies for Personalized Care.International journal of dentistry · 2026Review
- Biomechanical behavior of immediately placed implant using bone graft and socket shield techniques: a 3D finite element analysis.Head & face medicine · 2025Article
- Stress distribution on the components of multi-unit abutment with different angulation under lateral force: a finite element analysis.Clinical oral investigations · 2025Article
- DFT-based investigation of polyetherketoneketone materials for surface modification for dental implants.European journal of medical research · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe success of implants in the socket shield technique relies on stress experienced by root fragments within the socket. Although there is no consensus on optimal root fragment thickness, varying thicknesses and dynamic implant placement induce stress in various directions and degrees. This study aimed to assess biomechanical response and stress distribution across different root fragment thicknesses in the socket shield procedure.
methodsThis in vitro study was conducted to assess and compare the stress distribution on residual root structures of varying thicknesses positioned within the labial aspect of the maxillary incisor socket during immediate implant placement of standard dimensions. The procedure involved applying an insertional torque of 40 Ncm, and the analysis was conducted using finite element analysis software.
resultsUtilizing the Numerical Technique with Abaqus software for explicit dynamics, von Mises stress and principal strain were analyzed on the root structure and bone under nonlinear contact conditions during implant torque application. For Model A, a loading torque of 40 Ncm was applied vertically on the implant, along with a horizontal force of 20 N on the root structure and bone. Results indicated maximum stress of 12.68 MPa on the root structure with a thickness of 0.5 mm and 5.61 MPa on the bone, with principal strains of 6.82E-03 and 4.10E-03, respectively. In Model B, with a root structure thickness of 1.0 mm, the maximum stress increased to 19.70 MPa, while the bone stress rose to 9.51 MPa, with principal strains of 1.03E-02 and 6.09E-03. Model C, with a root structure thickness of 1.5 mm, exhibited a maximum stress of 21.58 MPa on the root and 10.12 MPa on the bone, with principal strains of 1.16E-02 and 6.10E-03. Lastly, in Model D, with a root structure thickness of 2.0 mm, the maximum stress on the root structure and bone escalated to 28.74 MPa and 11.38 MPa, respectively, with principal strains of 1.55E-02 and 8.31E-03.
conclusionsAs the thickness of the shield increases (ranging from 0.5 to 2 mm) in socket shield procedures with immediate implant placement, both stress on the root fragment and bone and principal micro-strain escalate. However, employing a shield thickness within the range of 0.5 to 2 mm does not lead to any adverse stress generation on the residual root fragment. However, for enhanced safety, it is recommended to restrict the maximum diameter and extension of the root fragment to 1.5 mm when considering implant sizes and socket diameter for the socket shield technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.