Evidence map›Paper›PMID 38514678›Full record

ArticleScientific reports2024

Analysis of the air stream flow parameters generated by the positive pressure ventilator-full scale experiment and CFD simulation.

Piotr Kaczmarzyk, Daniel Małozięć, Tomasz Burdzy, Bartosz Ziegler, Piotr Krawiec, Anna Dziechciarz, Łukasz Warguła

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Piotr KaczmarzykScience and Research Centre for Fire Protection, National Research Institute, 05-420, Józefów, Poland. pkaczmarzyk@cnbop.pl.ORCID http://orcid.org/0000-0003-4310-6086
Daniel MałozięćScience and Research Centre for Fire Protection, National Research Institute, 05-420, Józefów, Poland.ORCID http://orcid.org/0000-0003-4929-8656
Tomasz BurdzyDepartment of Environmental Engineering, Faculty of Civil Engineering and Resource Management, AGH University, Kraków, Poland.ORCID http://orcid.org/0000-0002-1225-5583
Bartosz ZieglerInstitute of Thermal Energy, Faculty of Environmental and Energy Engineering, Poznań University of Technology, 60-965, Poznan, Poland.ORCID http://orcid.org/0000-0002-0545-3805
Piotr KrawiecInstitute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology, 60-965, Poznan, Poland.ORCID http://orcid.org/0000-0003-3076-0337
Anna DziechciarzScience and Research Centre for Fire Protection, National Research Institute, 05-420, Józefów, Poland.ORCID http://orcid.org/0000-0003-4014-7819
Łukasz WargułaInstitute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology, 60-965, Poznan, Poland.ORCID http://orcid.org/0000-0002-3120-778X

Funding

Ministerstwo Edukacji i Nauki DWD/4/22/2020
6 · The paper itself

Abstract

Positioning the positive pressure ventilator in front of the door opening affects the effectiveness of the rescue operation carried out during a fire. An important factor determining the effectiveness of the positive pressure ventilator is also the layout of the rooms within the gas exchange path and the obstacles present there. The purpose of this article is to assess the feasibility of using analyses such as large eddy simulation (LES) to verify the efficiency of mobile fans under simulation conditions, without the need for time-consuming experimentation (also for complex room volumes of buildings). The article presents a comparative analysis to assess the degree of convergence of flow parameters obtained during an experiment (in a multi-story building) and computational fluid dynamics (CFD) simulations. For volumetric flow rate, convergence was achieved at levels ranging from 0.4% (for 5 m) to 11.5% (1 m), and for pressure values, the differences achieved ranged from 0.6% (5 m) to 30.1% (4 m). This paper demonstrates that the LES model can be used to perform CFD simulations in the area of assessing the performance of a positive pressure ventilator. The article also describes a test methodology for determining the flow parameters of an air stream, which can be used to perform numerical simulations.

Identifiers

PMID38514678
PMCPMC10957909

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.