Evidence map›Paper›PMID 38514627›Full record

ArticleNature communications2024

An optofluidic antenna for enhancing the sensitivity of single-emitter measurements.

Luis Morales-Inostroza, Julian Folz, Ralf Kühnemuth, Suren Felekyan, Franz-Ferdinand Wieser, Claus A M Seidel, Stephan Götzinger, Vahid Sandoghdar

Abstract read
In one paragraph

Article in Nature communications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Luis Morales-Inostroza *Max Planck Institute for the Science of Light, 91058, Erlangen, Germany.
Julian Folz *Chair for Molecular Physical Chemistry, Heinrich Heine University Düsseldorf, 40225, Düsseldorf, Germany.ORCID http://orcid.org/0000-0001-8232-8787
Ralf KühnemuthChair for Molecular Physical Chemistry, Heinrich Heine University Düsseldorf, 40225, Düsseldorf, Germany.
Suren FelekyanChair for Molecular Physical Chemistry, Heinrich Heine University Düsseldorf, 40225, Düsseldorf, Germany.ORCID http://orcid.org/0000-0002-0554-4520
Franz-Ferdinand WieserMax Planck Institute for the Science of Light, 91058, Erlangen, Germany.
Claus A M SeidelChair for Molecular Physical Chemistry, Heinrich Heine University Düsseldorf, 40225, Düsseldorf, Germany. cseidel@hhu.de.ORCID http://orcid.org/0000-0002-5171-149X
Stephan GötzingerMax Planck Institute for the Science of Light, 91058, Erlangen, Germany.ORCID http://orcid.org/0000-0003-4975-0112
Vahid SandoghdarMax Planck Institute for the Science of Light, 91058, Erlangen, Germany. vahid.sandoghdar@mpl.mpg.de.ORCID http://orcid.org/0000-0003-2594-4801

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many single-molecule investigations are performed in fluidic environments, for example, to avoid unwanted consequences of contact with surfaces. Diffusion of molecules in this arrangement limits the observation time and the number of collected photons, thus, compromising studies of processes with fast or slow dynamics. Here, we introduce a planar optofluidic antenna (OFA), which enhances the fluorescence signal from molecules by about 5 times per passage, leads to about 7-fold more frequent returns to the observation volume, and significantly lengthens the diffusion time within one passage. We use single-molecule multi-parameter fluorescence detection (sm-MFD), fluorescence correlation spectroscopy (FCS) and Förster resonance energy transfer (FRET) measurements to characterize our OFAs. The antenna advantages are showcased by examining both the slow (ms) and fast (50 μs) dynamics of DNA four-way (Holliday) junctions with real-time resolution. The FRET trajectories provide evidence for the absence of an intermediate conformational state and introduce an upper bound for its lifetime. The ease of implementation and compatibility with various microscopy modalities make OFAs broadly applicable to a diverse range of studies.

Identifiers

PMID38514627
PMCPMC10957926

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.