ArticleProceedings of the National Academy of Sciences of the United States of America2024
Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing.
Article in Proceedings of the National Academy of Sciences of the United States of America, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Novel OA-ICOS Sensor for Real-Time Quantification of Enteric Methane from Ruminants.Sensors (Basel, Switzerland) · 2026Article
- OpticalAnalytical chemistry · 2025Article
- Review
- Off-Axis Integral Cavity Carbon Dioxide Gas Sensor Based on Machine-Learning-Based Optimization.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump-probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ([Formula: see text]CO[Formula: see text]) molecules in room-temperature CO[Formula: see text] samples, with 1.4 parts-per-quadrillion (ppq, 10[Formula: see text]) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with [Formula: see text]C/C up to [Formula: see text]1.5[Formula: see text] natural abundance ([Formula: see text]1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO[Formula: see text] isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for [Formula: see text]CO[Formula: see text] benefits a wide range of scientific fields that utilize [Formula: see text]C for dating and isotope tracing, most notably atmospheric [Formula: see text]CO[Formula: see text] monitoring to track CO[Formula: see text] emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.