Evidence map›Paper›PMID 38512833›Full record

ArticlePloS one2024

The development, feasibility and credibility of intra-abdominal pressure measurement techniques: A scoping review.

ZhiRu Li, HuaFen Wang, FangYan Lu

Abstract readScoping Review
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Observational
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

ZhiRu LiNursing Department, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.
HuaFen WangNursing Department, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.ORCID 0000-0002-4674-4000
FangYan LuHepatobiliary and pancreatic surgery, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo provide a comprehensive overview on emerging direct and alternative methods for intra-abdominal pressure (IAP) measurement techniques.

methodsThis was a scoping review study following Arksey and Malley's framework. The PubMed, EMBASE, Web of Science, EBSCO, Scopus and ProQuest databases were searched, and we only considered studies published from 2000 as we have extended the data from two previous reviews. Original studies that reported on the development, feasibility and credibility of IAP measurement techniques were included.

resultsForty-two of 9954 screened articles were included. IAP measurement techniques include three major categories: direct, indirect and less invasive measurement techniques. Agreement analyses were performed in most studies, and some explored the safety, time expenditure and reproducibility of IAP measurement techniques.

conclusionsClinical data assessing the validation of new IAP measurement techniques or the reliability of established measurement techniques remain lacking. Considering the cost and invasiveness, direct measurement is not recommended as a routine method for IAP measurement and should be preserved for critically ill patients where standard techniques are contraindicated or could be inaccurate. The measurement accuracy, reliability and sensitivity of the transrectal and transfemoral vein methods remain insufficient and cannot be recommended as surrogate IAP measures. Transvesical measurement is the most widely used method, which is the potentially most easy applicable technique and can be used as a reliable method for continuous and intermittent IAP measurement. Wireless transvaginal method facilitates the quantitative IAP measurement during exercise and activity, which laying the foundations for monitoring IAP outside of the clinic environment, but the accuracy of this technique in measuring absolute IAP cannot be determined at present. Less invasive technology will become a new trend to measure IAP and has substantial potential to replace traditional IAP measurement technologies, but further validation and standardization are still needed. Medical professionals should choose appropriate measurement tools based on the advantages and disadvantages of each IAP technique in combination with assessing specific clinical situations.

Indexed as

Critical IllnessIntra-Abdominal HypertensionAbdomenFeasibility StudiesHumansReproducibility of ResultsTechnology

Identifiers

PMID38512833
PMCPMC10956852

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.