Evidence map›Paper›PMID 38512825›Full record

ArticlePloS one2024

Evaluation of a rapid Loop Mediated Isothermal Amplification (LAMP) test for the laboratory diagnosis of sexually transmitted infections.

Martina Brandolini, Laura Grumiro, Patrizia Farabegoli, Giorgio Dirani, Silvia Zannoli, Irene Zaghi, Massimiliano Guerra, Francesca Taddei, Giulia Gatti, Anna Marzucco and 5 more

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Martina BrandoliniUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.ORCID 0009-0002-1558-032X
Laura GrumiroUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.ORCID 0000-0003-2297-3009
Patrizia FarabegoliUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Giorgio DiraniUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Silvia ZannoliUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Irene ZaghiUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Massimiliano GuerraUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Francesca TaddeiUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Giulia GattiUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Anna MarzuccoUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.ORCID 0009-0003-3236-6525
Maria Sofia MontanariUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Alessandra Mistral De PascaliUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.ORCID 0000-0002-8662-0782
Simona SempriniUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Monica CriccaUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.
Vittorio SambriUnit of Microbiology, The Greater Romagna Area Hub Laboratory, Cesena, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Sexually transmitted infections (STIs) have seen a considerable increase in the last years and given the health burden they may represent from both a personal and community perspective, they require surveillance and prevention programmes based on a timely and decentralized diagnosis. In this context, user-friendly rapid molecular tests may represent a good trade-off between diagnostic accuracy, accessibility and affordability. In this study we evaluated the diagnostic performance of a new real-time LAMP (Loop Mediated Isothermal Amplification) method for the rapid detection and differentiation of 7 major sexually transmissible pathogens by analysing real clinical samples (genital and extra-genital matrices) from individuals with suspected STIs. The assay showed good overall diagnostic performances in terms of sensitivity, specificity and concordance with a gold-standard PCR-based molecular method. This assay, not requiring specialised laboratory technicians or expensive instrumentation, but nonetheless capable of guaranteeing accurate results, is within the reach of outpatient settings, obstetrics, and gynaecology clinic, hence ensuring on-field access to early diagnosis.

Indexed as

Clinical Laboratory TechniquesSexually Transmitted DiseasesFemaleHumansMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesPregnancySensitivity and Specificity

Identifiers

PMID38512825
PMCPMC10956856

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.