Evidence map›Paper›PMID 38509336›Full record

ArticleInternational journal of implant dentistry2024

Effects of the application of low-temperature atmospheric plasma on titanium implants on wound healing in peri-implant connective tissue in rats.

Atsuro Harada, Hodaka Sasaki, Yosuke Asami, Kiyotoshi Hanazawa, Sota Miyazaki, Hideshi Sekine, Yasutomo Yajima

Open access · diamondAbstract read
In one paragraph

Article in International journal of implant dentistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.5field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Dual-Targeted Biomimetic MoSeAdvanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Atsuro HaradaDepartment of Oral and Maxillofacial Implantology, Tokyo Dental College, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan.
Hodaka SasakiDepartment of Oral and Maxillofacial Implantology, Tokyo Dental College, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan. hosasaki@tdc.ac.jp.ORCID 0000-0001-9071-6042
Yosuke AsamiDepartment of Oral and Maxillofacial Implantology, Tokyo Dental College, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan.
Kiyotoshi HanazawaDepartment of Oral and Maxillofacial Implantology, Tokyo Dental College, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan.
Sota MiyazakiDepartment of Oral and Maxillofacial Implantology, Tokyo Dental College, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan.
Hideshi SekineDepartment of Fixed Prosthodontics, Tokyo Dental College, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan.
Yasutomo YajimaDepartment of Oral and Maxillofacial Implantology, Tokyo Dental College, 2-9-18 Kandamisaki-Cho, Chiyoda-Ku, Tokyo, 101-0061, Japan.
Tokyo Dental College · JP

Funding

KAKENHI Grant-in-Aid for Scientific Research (C 22K10023
6 · The paper itself

Abstract

purposeThis study aimed to clarify the effects of surface modification of titanium (Ti) implants by low-temperature atmospheric pressure plasma treatment on wound healing and cell attachment for biological sealing in peri-implant soft tissue.

methodsHydrophilization to a Ti disk using a handheld low-temperature atmospheric pressure plasma device was evaluated by a contact angle test and compared with an untreated group. In in vivo experiments, plasma-treated pure Ti implants using a handheld plasma device (experimental group: PL) and untreated implants (control group: Cont) were placed into the rat upper molar socket, and samples were harvested at 3, 7 and 14 days after surgery. Histological evaluation was performed to assess biological sealing, collagen- and cell adhesion-related gene expression by reverse transcription quantitative polymerase chain reaction, collagen fiber detection by Picrosirius Red staining, and immunohistochemistry for integrins.

resultsIn in vivo experiments, increased width of the peri-implant connective tissue (PICT) and suppression of epithelial down growth was observed in PL compared with Cont. In addition, high gene expression of types I and XII collagen at 7 days and acceleration of collagen maturation was recognized in PL. Strong immunoreaction of integrin α2, α5, and β1 was observed at the implant contact area of PICT in PL.

conclusionsThe handheld low-temperature atmospheric pressure plasma device provided hydrophilicity on the Ti surface and maintained the width of the contact area of PICT to the implant surface as a result of accelerated collagen maturation and fibroblast adhesion, compared to no plasma application.

Indexed as

Dental ImplantsAnimalsCollagenConnective TissueRatsSurface PropertiesTemperatureTitaniumWound HealingCollagenDental ImplantsTitaniumCollagenDental implantHandheld low-temperature atmospheric pressure plasmaIntegrinPeri-implant connective tissueWound healing

Identifiers

PMID38509336
PMCPMC10954594
OpenAlexW4393052879

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.