Evidence map›Paper›PMID 38507479›Full record

ArticleScience advances2024

Parametric magnon transduction to spin qubits.

Mauricio Bejarano, Francisco J T Goncalves, Toni Hache, Michael Hollenbach, Christopher Heins, Tobias Hula, Lukas Körber, Jakob Heinze, Yonder Berencén, Manfred Helm and 3 more

Abstract read
In one paragraph

Article in Science advances, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Magnon-induced electric polarization and magnon Nernst effects.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Mauricio BejaranoHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0001-5970-0384
Francisco J T GoncalvesHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0002-1671-437X
Toni HacheHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0001-8245-5153
Michael HollenbachHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.
Christopher HeinsHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0001-9297-3798
Tobias HulaHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0002-1811-8862
Lukas KörberHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0001-8332-9669
Jakob HeinzeHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.
Yonder BerencénHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0003-3529-0207
Manfred HelmHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0001-8986-9914
Jürgen FassbenderHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0003-3893-9630
Georgy V AstakhovHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0003-1807-3534
Helmut SchultheissHelmholtz-Zentrum Dresden-Rossendorf, Institute for Ion Beam Physics and Materials Research, 01328 Dresden, Germany.ORCID 0000-0002-6727-5098

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The integration of heterogeneous modular units for building large-scale quantum networks requires engineering mechanisms that allow suitable transduction of quantum information. Magnon-based transducers are especially attractive due to their wide range of interactions and rich nonlinear dynamics, but most of the work to date has focused on linear magnon transduction in the traditional system composed of yttrium iron garnet and diamond, two materials with difficult integrability into wafer-scale quantum circuits. In this work, we present a different approach by using wafer-compatible materials to engineer a hybrid transducer that exploits magnon nonlinearities in a magnetic microdisc to address quantum spin defects in silicon carbide. The resulting interaction scheme points to the unique transduction behavior that can be obtained when complementing quantum systems with nonlinear magnonics.

Identifiers

PMID38507479
PMCPMC10954226

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.