Evidence map›Paper›PMID 38507097›Full record

ArticleWorld journal of urology2024

Feasibility of stereotactic optical navigation for needle positioning in percutaneous nephrolithotomy.

I M Spenkelink, X Zhu, J J Fütterer, J F Langenhuijsen

Open access · hybridAbstract read
In one paragraph

Article in World journal of urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

I M SpenkelinkDepartment of Medical Imaging, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands. Ilse.Spenkelink@radboudumc.nl.ORCID http://orcid.org/0000-0003-3772-2851
X ZhuDepartment of Urology, Radboud University Medical Center, Nijmegen, The Netherlands.
J J FüttererDepartment of Medical Imaging, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
J F LangenhuijsenDepartment of Urology, Radboud University Medical Center, Nijmegen, The Netherlands.
Radboud University Nijmegen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study assessed the feasibility of acquiring single-attempt access to the pelvicalyceal system during percutaneous nephrolithotomy (PCNL) using stereotactic optical navigation combined with cone-beam CT (CBCT) imaging.

methodsPatients with a PCNL indication were prospectively included in this IRB approved study. After sterile preparation, fiducial markers were attached to patients' skin. An initial intraprocedural CBCT scan was acquired, on which the urologist planned the needle trajectory using the navigation software. After verifying that no critical structures were crossed, the needle guide was aligned with the plan. A needle was manually inserted through the needle guide to the indicated depth and a second CBCT scan was performed for needle position confirmation. Both, scanning and needle insertion, were performed under apnea. The study evaluated technical success, accuracy, procedure time, complication rate, and radiation dose.

resultsBetween June 2022 and April 2023, seven patients were included. In all patients, the navigation system allowed safe puncture. However, the technical success rate was only 29%. In 42% of the cases, pelvicalyceal access was achieved by a small manual adjustment. In the remaining 29%, the needle was retracted and positioned per clinical standard. The average deviation between the needle and target was 5.9 ± 2.3 mm. The average total procedure time was 211 ± 44 min. The average radiation exposure was 6.4 mSv, with CBCT scanning contributing to 82% of this exposure.

conclusionsThe optical navigation system facilitated safe needle insertion but did not consistently ensure accurate one-attempt needle positioning for PCNL. Real-time visualization and trajectory correction may improve the technical success rate.

Indexed as

Nephrolithotomy, PercutaneousCone-Beam Computed TomographyFeasibility StudiesHumansKidneyPuncturesCBCT imagingNavigated needle positioningOptical navigationPercutaneous nephrolithotomyStereotactic navigation

Identifiers

PMID38507097
PMCPMC10954992
OpenAlexW4392986298

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.