Evidence map›Paper›PMID 38505093›Full record

ArticleGMS hygiene and infection control2024

Can the adenosine triphosphate (ATP) bioluminescence assay be used as an indicator for hospital cleaning? - A pilot study.

Valerie Niephaus, Nina Parohl, Sabine Heiligtag, Henning Reuter, Reiner Hackler, Walter Popp

Open access · greenAbstract read
In one paragraph

Article in GMS hygiene and infection control, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. A successfully shortened outbreak of vancomycin-resistantAntimicrobial stewardship & healthcare epidemiology : ASHE · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Valerie NiephausEvang. Kliniken Essen-Mitte, Essen, Germany.
Nina ParohlHyKoMed GmbH, Dortmund, Germany.
Sabine Heiligtag3M Deutschland GmbH, Neuss, Germany.
Henning Reuter3M Deutschland GmbH, Neuss, Germany.
Reiner Hackler3M Deutschland GmbH, Neuss, Germany.
Walter PoppHyKoMed GmbH, Dortmund, Germany.
3M (Germany) · DEElmos Semiconductor (Germany) · DEKliniken Essen-Mitte · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In hospital cleaning, there is currently no standard for uniform monitoring of surface cleaning, either in Germany or internationally. One possibility for monitoring is the use of so-called objective methods for checking cleaning performance (e.g. fluorescence or adenosine triphosphate (ATP) method). Aim: The aim of the study was to monitor and evaluate the implementation of the adenosine triphosphate (ATP) bioluminescence assay as a cleaning indicator in everyday hospital cleaning, in order to verify its utility and effectiveness. Methods: In three phases, five frequently touched surfaces were examined with the ATP bioluminescence assay at different time points. 846 measurements were performed on the dermatology ward of a university hospital (phase 1), 1,350 measurements were performed on five different wards of the university hospital (phase 2), and 1,044 measurements were performed on five wards of another large hospital (phase 3). For this purpose, one structurally old and one structurally new ward as well as an intensive care unit (ICU), an outpatient clinic and a radiology department were selected for phases 2 and 3. Results: With the ATP bioluminescence method, we were able to demonstrate a reduction in values after cleaning: before cleaning mean of ATP, 907 relative light units (RLU) (95% confidence interval [CI] 777; 1,038); after cleaning mean=286 RLU (CI=233; 495) (phase 1) and by intervention (five hours after daily cleaning mean=360 RLU (CI=303; 428); five hours after daily cleaning and two additional cleanings mean=128 RLU (CI=107; 152) (phase 3). The ATP values increased five hours after cleaning in phases 1 and 2, and eight hours after cleaning in phase 3. The structurally old wards had the highest ATP content, the ICU and the radiology department, among others, the lowest. In all phases, door handles showed both a reduction after cleaning or intervention and a subsequent increase in ATP values. Chair armrests, examination tables and door handles had high ATP values overall. Conclusion: The study shows ward differences both for cleaning effects and for the soiling characteristics of surfaces during the course of the day. In addition, it demonstrates the benefit of intermediate cleaning twice a day. It is noteworthy that structurally old stations and older inventory were more heavily soiled and, in some cases, more difficult to clean. The results show that the ATP bioluminescence method is suitable for detecting cleaning effects and can be used in everyday clinical practice for simple cleaning monitoring. Furthermore, it enables the detection of risk surfaces and easy-to-clean surfaces with significant re-soiling.

Indexed as

adenosine triphosphate bioluminescenceATPcleaning monitoringhealthcare-associated infectionshospital cleaning

Identifiers

PMID38505093
PMCPMC10949084
OpenAlexW4394760828

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked