Evidence map›Paper›PMID 38504836›Full record

ArticleInternational journal of applied & basic medical research

Interdevice Agreement between a Smartphone and a Commercial Pupillometer.

Yamini Rattan, Kawalinder Kaur Girgla, Gaurav Mahajan, Pawan Prasher

Abstract read
In one paragraph

Article in International journal of applied & basic medical research. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yamini RattanDepartment of Physiology, Sri Guru Ram Das Institute of Medical Sciences and Research, Amritsar, Punjab, India.
Kawalinder Kaur GirglaDepartment of Physiology, Sri Guru Ram Das Institute of Medical Sciences and Research, Amritsar, Punjab, India.
Gaurav MahajanDepartment of Ophthalmology, Sri Guru Ram Das Institute of Medical Sciences and Research, Amritsar, Punjab, India.
Pawan PrasherDepartment of Ophthalmology, Sri Guru Ram Das Institute of Medical Sciences and Research, Amritsar, Punjab, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The reliability of dynamic pupillometry parameters varies from one pupillometer to another, making it difficult to standardize the values for any particular device. Hence, further studies are required to evaluate the agreement of various pupillometer devices and explore their utility in routine clinical settings. Aim: This study sought to evaluate the agreement between smartphone and commercial pupillometer measurements in routine clinical settings. Methods: The study included pupillary measurements obtained by a single investigator from 100 healthy participants (200 eyes) with each pupillometer. Pupillary measurements taken by a smartphone pupillometry application (reflex pupillary light reflex analyzer by Brightlamp [Indianapolis, IN, USA]) were compared with a commercial pupillometer (neurological pupil index-200, NeurOptics Inc., Irvine, USA). Results: The comparison of descriptive statistics revealed a statistically significant difference between the smartphone and commercial pupillometers for various parameters, including maximum diameter, minimum diameter, constriction velocity (CV), maximum CV, and dilatation velocity ( Conclusion: The measurements by smartphone pupillometry application were found to be unreliable, indicating that they may not be an ideal substitute for commercial pupillometers in their present form in the Indian population. Further studies with larger sample size as well as improvements in the processing and interpretation of the measurements by the software, are needed to determine its utility in routine clinical settings.

Indexed as

Commercial pupillometerIndian populationpupillary parameterssmartphone pupillometer

Identifiers

PMID38504836
PMCPMC10947756

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.