ArticleMagnetic resonance in medicine2024
Increasing the scan-efficiency of pulmonary imaging at 0.55 T using iterative concomitant field and motion-corrected reconstruction.
Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 9 citations in OpenAlex.
- "Two-For-One": 4D Cardiac and Pulmonary MR Imaging From a Single Acquisition Using bSTAR.Magnetic resonance in medicine · 2026Trial
- Comparison of Signal- and Volume-Based Ventilation-Weighted Assessment Using 3D FLORET UTE MRI in Patients With Various Pulmonary Disease.Magnetic resonance in medicine · 2026Article
- A longitudinal study of quantitative pulmonary dynamic contrast enhanced MRI following COVID-19 infection.Respiratory research · 2026Article
- Cartesian MaxGIRF: Model-based EPI reconstruction incorporating gradient nonlinearity and concomitant field effects.Magnetic resonance in medicine · 2026Article
- Magnetic Resonance Imaging in the Clinical Evaluation of Lung Disorders: Current Status and Future Prospects.Journal of magnetic resonance imaging : JMRI · 2025Review
- Single breath-hold volumetric lung imaging at 0.55T using stack-of-spiral (SoS) out-in balanced SSFP.Magnetic resonance in medicine · 2025Article
- Isotropic three-dimensional cardiac cine imaging at 0.55T using stack-of-spiral sampling and four-dimensional iterative motion compensation.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic ResonanceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
Abstract
purposeTo develop an iterative concomitant field and motion corrected (iCoMoCo) reconstruction for isotropic high-resolution UTE pulmonary imaging at 0.55 T.
methodsA free-breathing golden-angle stack-of-spirals UTE sequence was used to acquire data for 8 min with prototype and commercial 0.55 T MRI scanners. The data was binned into 12 respiratory phases based on superior-inferior navigator readouts. The previously published iterative motion corrected (iMoCo) reconstruction was extended to include concomitant field correction directly in the cost function. The reconstruction was implemented within the Gadgetron framework for inline reconstruction. Data were retrospectively reconstructed to simulate scan times of 2, 4, 6, and 8 min. Image quality was assessed using apparent SNR and image sharpness. The technique was evaluated in healthy volunteers and patients with known lung pathology including coronavirus disease 2019 infection, chronic granulomatous disease, lymphangioleiomyomatosis, and lung nodules.
resultsThe technique provided diagnostic-quality images, and image quality was maintained with a slight loss in SNR for simulated scan times down to 4 min. Parenchymal apparent SNR was 4.33 ± 0.57, 5.96 ± 0.65, 7.36 ± 0.64, and 7.87 ± 0.65 using iCoMoCo with scan times of 2, 4, 6, and 8 min, respectively. Image sharpness at the diaphragm was comparable between iCoMoCo and reference images. Concomitant field corrections visibly improved the sharpness of anatomical structures away from the isocenter. Inline image reconstruction and artifact correction were achieved in <5 min.
conclusionThe proposed iCoMoCo pulmonary imaging technique can generate diagnostic quality images with 1.75 mm isotropic resolution in less than 5 min using a 6-min acquisition, on a 0.55 T scanner.
Indexed as
Identifiers
What OpenQuestion holds