A target containing phantom for accuracy assessment of cone-beam CT-guided histotripsy.

Ayca Z Kutlu, Grace M Minesinger, Paul F Laeseke, Michael Speidel, Martin G Wagner

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.8field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Ayca Z KutluDepartment of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.ORCID https://orcid.org/0000-0003-4561-3786
Grace M MinesingerDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Paul F LaesekeDepartment of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Michael SpeidelDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Martin G WagnerDepartment of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
University of Wisconsin–Madison · US

Funding

Advanced multimodal image-guided histotripsy for precise, safe and effective histotripsy of liver tumorsR01EB031007 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI Paul F Laeseke, Martin Gerd Wagner · 2022 to 2026
$2.5M
NIBIB NIH HHS R01 EB031007NIBIB NIH HHS R01EB031007
6 · The paper itself

Abstract

purposeHistotripsy is a nonionizing, noninvasive, and nonthermal focal tumor therapy. Cone-beam computed tomography (CBCT) guidance was developed for targeting tumors not visible on ultrasound. This approach assumes cavitation is formed at the geometrical focal point of the therapy transducer. In practice, the exact location might vary slightly between transducers. In this study, we present a phantom with an embedded target to evaluate CBCT-guided histotripsy accuracy and assess the completeness of treatments.

methodsSpherical (2.8 cm) targets with alternating layers of agar and radiopaque barium were embedded in larger phantoms with similar layers. The layer geometry was designed so that targets were visible on pre-treatment CBCT scans. The actual histotripsy treatment zone was visualized via the mixing of adjacent barium and agar layers in post-treatment CBCT images. CBCT-guided histotripsy treatments of the targets were performed in six phantoms. Offsets between planned and actual treatment zones were measured and used for calibration refinement. To measure targeting accuracy after calibration refinement, six additional phantoms were treated. In a separate investigation, two groups (N = 3) of phantoms were treated to assess visualization of incomplete treatments ("undertreatment" group: 2 cm treatment within 2.8 cm tumor, "mistarget" group: 2.8 cm treatment intentionally shifted laterally). Treatment zones were segmented (3D Slicer 5.0.3), and the centroid distance between the prescribed target and actual treatment zones was quantified.

resultsIn the calibration refinement group, a 2 mm offset in the direction of ultrasound propagation (Z) was measured. After calibration refinement, the centroid-to-centroid distance between prescribed and actual treatment volumes was 0.5 ± 0.2 mm. Average difference between the prescribed and measured treatment sizes in the incomplete treatment groups was 0.5 ± 0.7 mm. In the mistarget group, the distance between prescribed and measured shifts was 0.2 ± 0.1 mm.

conclusionThe proposed prototype phantom allowed for accurate measurement of treatment size and location, and the CBCT visible target provided a simple way to detect misalignments for preliminary quality assurance of CBCT-guided histotripsy.

Indexed as

Cone-Beam Computed TomographyPhantoms, ImagingHumansImage Processing, Computer-AssistedNeoplasmsaccuracy improvementcone beam CThistotripsyphantomquality assurancetargeting

Identifiers

PMID38497567
PMCPMC11087156
OpenAlexW4392913089

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.