ArticleJournal of medical biochemistry2024
Six SIGMA evaluation of 17 biochemistry parameters using bias calculated from internal quality control and external quality assurance data.
Article in Journal of medical biochemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 6 citations in OpenAlex.
- Six SIGMA-based quality assessment of biochemical analytes: A comparative analysis of clinical laboratory improvement amendments 1988 and 2024 standards.Journal of medical biochemistry · 2025Article
- Comparison of SYSMEX CN-6000 and STAGO STA-R: Effects of hemolysis and lipemia.Journal of medical biochemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Six Sigma is a popular quality management system that enables continuous monitoring and improvement of analytical performance in the clinical laboratory. We aimed to calculate sigma metrics and quality goal index (QGI) for 17 biochemical analytes and compare the use of bias from internal quality control (IQC) and external quality assurance (EQA) data in the calculation of sigma metrics. Methods: This retrospective study was conducted in Marmara University Pendik E&R Hospital Biochemistry Laboratory. Sigma metrics calculation was performed as (TEa-bias)/CV). CV was calculated from IQC data from June 2018 - February 2019. EQA bias was calculated as the mean of % deviation from the peer group means in the last seven surveys, and IQC bias was calculated as (laboratory control result mean-manufacturer control mean)/ manufacturer control mean) x100. In parameters where sigma metrics were <5; QGI=bias/1.5 CV) score of <0.8 indicated imprecision, >1.2 pointed inaccuracy, and 0.8-1.2 showed both imprecision and inaccuracy. Results: Creatine kinase (both levels), iron and magnesium (pathologic levels) showed an ideal performance with ≥6 sigma level for both bias determinations. Eight of the 17 parameters had different sigma levels when we compared sigma values calculated from EQA and IQC derived bias% while the rest were grouped at the same levels. Conclusions: Sigma metrics is a good quality tool to assess a laboratory's analytical performance and facilitate the comparison of the assay performances in the same manner across multiple systems. However, we might need to design a tight internal quality control protocol for analytes showing poor assay performance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.