Evidence map›Paper›PMID 38495705›Full record

ArticleBiomedical optics express2024

Beyond synthetic aperture focusing: deconvolution-based elevation resolution enhancement using simulated point spread function for linear array-based three-dimensional photoacoustic imaging.

Yichuan Tang, Wojciech G Lesniak, Shang Gao, Yixuan Wu, Martin G Pomper, Haichong K Zhang

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 58% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Yichuan TangDepartment of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA.ORCID https://orcid.org/0000-0003-1681-5944
Wojciech G LesniakRussell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, 3400 N. Charles St, Baltimore, MD 21218, USA.
Shang GaoDepartment of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA.ORCID https://orcid.org/0000-0001-9921-7899
Yixuan WuDepartment of Computer Science, Johns Hopkins University, 3400 N. Charles St, Baltimore, MD 21218, USA.
Martin G PomperRussell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, 3400 N. Charles St, Baltimore, MD 21218, USA.
Haichong K ZhangDepartment of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA.ORCID https://orcid.org/0000-0002-1314-8456
Johns Hopkins University · USWorcester Polytechnic Institute · US

Funding

PSMA-based Cancer Imaging AgentsR01CA134675 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI POMPER, MARTIN G · 2009 to 2025
$6.2M
Robotic Lung Ultrasound for Triage of COVID-19 Patients in a Resource-Limited EnvironmentDP5OD028162 · OD · WORCESTER POLYTECHNIC INSTITUTE · PI ZHANG, HAICHONG · 2019 to 2023
$2.3M
NCI NIH HHS R01 CA134675NIH HHS DP5 OD028162
6 · The paper itself

Abstract

This paper introduces a deconvolution-based method to enhance the elevation resolution of a linear array-based three-dimensional (3D) photoacoustic (PA) imaging system. PA imaging combines the high contrast of optical imaging with the deep, multi-centimeter spatial resolution of ultrasound (US) imaging, providing structural and functional information about biological tissues. Linear array-based 3D PA imaging is easily accessible and applicable for ex vivo studies, small animal research, and clinical applications in humans. However, its elevation resolution is limited by the acoustic lens geometry, which establishes a single elevation focus. Previous work used synthetic aperture focusing (SAF) to enhance elevation resolution, but the resolution achievable by SAF is constrained by the size of the elevation focus. Here, we introduce the application of Richardson-Lucy deconvolution, grounded in simulated point-spread-functions, to surpass the elevation resolution attainable with SAF alone. We validated this approach using both simulation and experimental data, demonstrating that the full-width-at-half-maximum of point targets on the elevation plane was reduced compared to using SAF only, suggesting resolution improvement. This method shows promise for improving 3D image quality of existing linear array-based PA imaging systems, offering potential benefits for disease diagnosis and monitoring.

Identifiers

PMID38495705
PMCPMC10942676
OpenAlexW4391651347

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.