Evidence map›Paper›PMID 38495704›Full record

ArticleBiomedical optics express2024

Rhodamine-based fluorescent probe for dynamic STED imaging of mitochondria.

Xinwei Gao, Songtao Cai, Luwei Wang, Yong Guo, Liwei Liu, Xiaoyu Weng, Kun Huang, Wei Yan, Junle Qu

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Xinwei GaoKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Songtao CaiKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Luwei WangKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Yong GuoKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Liwei LiuKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Xiaoyu WengKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.ORCID https://orcid.org/0000-0001-9654-3517
Kun HuangSchool of Chemistry and Chemical Engineering, China West Normal University, Nanchong 637002, China.
Wei YanKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.ORCID https://orcid.org/0000-0002-0745-9514
Junle QuKey Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.ORCID https://orcid.org/0000-0001-7833-4711
Shenzhen University · CNChina West Normal University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stimulated emission depletion (STED) microscopy holds tremendous potential and practical implications in the field of biomedicine. However, the weak anti-bleaching performance remains a major challenge limiting the application of STED fluorescent probes. Meanwhile, the main excitation wavelengths of most reported STED fluorescent probes were below 500 nm or above 600 nm, and few of them were between 500-600 nm. Herein, we developed a new tetraphenyl ethylene-functionalized rhodamine dye (TPERh) for mitochondrial dynamic cristae imaging that was rhodamine-based with an excitation wavelength of 560 nm. The TPERh probe exhibits excellent anti-bleaching properties and low saturating stimulated radiation power in mitochondrial STED super-resolution imaging. Given these outstanding properties, the TPERh probe was used to measure mitochondrial deformation, which has positive implications for the study of mitochondria-related diseases.