ArticleMicrosystems & nanoengineering2024
A resonant high-pressure microsensor based on a composite pressure-sensitive mechanism of diaphragm bending and volume compression.
Article in Microsystems & nanoengineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 14 citations in OpenAlex.
- Research on Temperature Compensation Technology for a Flexible Capacitive Pressure Sensing System.Micromachines · 2026Article
- A Silicon Resonant Pressure Microsensor Based on Frequency-Ratio Measurement for High-Temperature Applications.Micromachines · 2026Article
- Bifurcation-based wide-range vacuum pressure micro-sensor.Scientific reports · 2025Article
- A 70 MPa silicon resonant pressure microsensor with resonators supported by micro beams based on volume compressed sensing.Microsystems & nanoengineering · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this paper, a composite pressure-sensitive mechanism combining diaphragm bending and volume compression was developed for resonant pressure microsensors to achieve high-pressure measurements with excellent accuracy. The composite mechanism was explained, and the sensor structure was designed based on theoretical analysis and finite element simulation. An all-silicon resonant high-pressure microsensor with multiple miniaturized cavities and dual resonators was developed, where dual resonators positioned in two resonant cavities with suitably different widths are used to perform opposite characteristics in pressure and the same characteristics at different temperatures, which can improve pressure sensitivities and realize temperature self-compensation by differential frequency output. The microsensor was fabricated by microfabrication, and the experimental results showed that the sensor had an accuracy of ±0.015% full scale (FS) in a pressure range of 0.1~100 MPa and a temperature range of -10~50 °C. The pressure sensitivity of the differential frequency was 261.10 Hz/MPa (~2523 ppm/MPa) at a temperature of 20 °C, and the temperature sensitivities of the dual resonators were -1.54 Hz/°C (~-14.5 ppm/°C) and -1.57 Hz/°C (~-15.6 ppm/°C) at a pressure of 2 MPa. The differential output had an outstanding stability within ±0.02 Hz under constant temperature and pressure. Thus, this research provides a convenient solution for high-pressure measurements because of its advantages, namely, large range, excellent accuracy and stability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.