Validation of a Wearable Virtual Reality Perimeter for Glaucoma Staging, The NOVA Trial: Novel Virtual Reality Field Assessment.
Article in Translational vision science & technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06549010 (A Pilot Study on the Repeatability of a Novel Perimetric Test Administered Via a Virtual Reality Headset.), which is not on this map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Pilot Study on the Repeatability of a Novel Perimetric Test Administered Via a Virtual Reality Headset.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Virtual reality perimetry compared to standard automated perimetry in adults with glaucoma: A systematic review.PloS one · 2025Pooled it
- Structure-Function Correlation of Virtual Reality and Standard Perimetry With Peripapillary RNFL OCT in Glaucoma Patients.Translational vision science & technology · 2026Article
- Evaluating the Clinical Validity of Commercially Available Virtual Reality Headsets for Visual Field Testing: A Systematic Review.Vision (Basel, Switzerland) · 2025Review
- Patient Comfort, Acceptance, and Tolerability of Virtual Reality (VR) Headsets with Real-Time Eye Tracking for Remote Visual Field Testing.Journal of clinical medicine · 2025Article
- Luminance and thresholding limitations of virtual reality headsets for visual field testing.PloS one · 2025Article
- Interventional Glaucoma: Improving the Patient-Provider Educational Exchange.Clinical ophthalmology (Auckland, N.Z.) · 2024Article
- Early diagnostics and interventional glaucoma.Therapeutic advances in ophthalmologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Compare estimated sensitivities of SITA-Standard to the RATA-Standard algorithm of the Radius virtual reality perimeter (VRP), and measure concordance in glaucoma staging. Methods: One hundred adult glaucoma patients-half with suspect or mild glaucoma, and half with moderate or severe-from five clinics performed four 24-2 visual field tests during a single visit, two with the Humphrey Field Analyzer (HFA) and two with Radius, in randomized order: HRHR or RHRH. Only one eye was tested per participant. We used the Wilcoxon rank sum test with Bonferroni correction to compare distributions of estimated sensitivities across all 54 test locations over the 15 to 40 dB measurement range of the Radius. Weighted kappa measured concordance in glaucoma staging between two masked glaucoma experts using Medicare definitions of severity. Results: A total of 62 OD and 38 OS eyes were tested. Estimated sensitivities for SITA-Standard and RATA-Standard were not significantly different for OD, but were for OS-likely because of SITA-Standard OD and OS being significantly different in our sample, but not for RATA-Standard. Low agreement was observed between 15 to 22 dB. Concordance in glaucoma staging was high for both graders: kappa = 0.91 and kappa = 0.93. Average test duration was 298 seconds for RATA-Standard and 341 seconds for SITA-Standard. The correlation in mean deviation was 0.94. Conclusions: Estimated sensitivities of RATA-Standard are comparable to SITA-Standard between 23 to 40 dB with high concordance in glaucoma staging. Translational Relevance: Radius VRP is statistically noninferior to HFA when staging glaucoma using Medicare definitions.