Evidence map›Paper›PMID 38486193›Full record

ArticleRadiation oncology (London, England)2024

Channel-wise attention enhanced and structural similarity constrained cycleGAN for effective synthetic CT generation from head and neck MRI images.

Changfei Gong, Yuling Huang, Mingming Luo, Shunxiang Cao, Xiaochang Gong, Shenggou Ding, Xingxing Yuan, Wenheng Zheng, Yun Zhang

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Changfei GongDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China.
Yuling HuangDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China.
Mingming LuoDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China.
Shunxiang CaoDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China.
Xiaochang GongDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China.
Shenggou DingDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China.
Xingxing YuanDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China.
Wenheng ZhengDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China.
Yun ZhangDepartment of Radiation Oncology, Jiangxi Cancer Hospital, 330029, Nanchang, Jiangxi, PR China. zhangyun_1983@sohu.com.

Funding

The Jiangxi Provincial Natural Science Foundation 20224BAB206070The Science and Technology Project of Jiangxi Provincial Health Commission of China .202310023
6 · The paper itself

Abstract

backgroundMagnetic resonance imaging (MRI) plays an increasingly important role in radiotherapy, enhancing the accuracy of target and organs at risk delineation, but the absence of electron density information limits its further clinical application. Therefore, the aim of this study is to develop and evaluate a novel unsupervised network (cycleSimulationGAN) for unpaired MR-to-CT synthesis.

methodsThe proposed cycleSimulationGAN in this work integrates contour consistency loss function and channel-wise attention mechanism to synthesize high-quality CT-like images. Specially, the proposed cycleSimulationGAN constrains the structural similarity between the synthetic and input images for better structural retention characteristics. Additionally, we propose to equip a novel channel-wise attention mechanism based on the traditional generator of GAN to enhance the feature representation capability of deep network and extract more effective features. The mean absolute error (MAE) of Hounsfield Units (HU), peak signal-to-noise ratio (PSNR), root-mean-square error (RMSE) and structural similarity index (SSIM) were calculated between synthetic CT (sCT) and ground truth (GT) CT images to quantify the overall sCT performance.

resultsOne hundred and sixty nasopharyngeal carcinoma (NPC) patients who underwent volumetric-modulated arc radiotherapy (VMAT) were enrolled in this study. The generated sCT of our method were more consistent with the GT compared with other methods in terms of visual inspection. The average MAE, RMSE, PSNR, and SSIM calculated over twenty patients were 61.88 ± 1.42, 116.85 ± 3.42, 36.23 ± 0.52 and 0.985 ± 0.002 for the proposed method. The four image quality assessment metrics were significantly improved by our approach compared to conventional cycleGAN, the proposed cycleSimulationGAN produces significantly better synthetic results except for SSIM in bone.

conclusionsWe developed a novel cycleSimulationGAN model that can effectively create sCT images, making them comparable to GT images, which could potentially benefit the MRI-based treatment planning.

Indexed as

Nasopharyngeal NeoplasmsNeckHeadHumansMagnetic Resonance ImagingTomography, X-Ray ComputedCycleGANMR-to-CT synthesisNasopharyngeal carcinomaUnsupervised networkVolumetric-modulated arc radiotherapy

Identifiers

PMID38486193
PMCPMC10938692

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked