Evidence map›Paper›PMID 38486064›Full record

ArticleScientific reports2024

Benchmarking long-read aligners and SV callers for structural variation detection in Oxford nanopore sequencing data.

Asmaa A Helal, Bishoy T Saad, Mina T Saad, Gamal S Mosaad, Khaled M Aboshanab

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
5.1field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Asmaa A HelalDepartment of Bioinformatics, HITS Solutions Co., Cairo, 11765, Egypt.
Bishoy T SaadDepartment of Bioinformatics, HITS Solutions Co., Cairo, 11765, Egypt. bishoyth@hitssolutions.com.
Mina T SaadDepartment of Bioinformatics, HITS Solutions Co., Cairo, 11765, Egypt.
Gamal S MosaadDepartment of Bioinformatics, HITS Solutions Co., Cairo, 11765, Egypt.
Khaled M AboshanabDepartment of Microbiology and Immunology, Faculty of Pharmacy, Ain Shams University, Organization of African Unity St., Abassi, Cairo, 11566, Egypt. aboshanab2012@pharma.asu.edu.eg.
Ain Shams University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Structural variants (SVs) are one of the significant types of DNA mutations and are typically defined as larger-than-50-bp genomic alterations that include insertions, deletions, duplications, inversions, and translocations. These modifications can profoundly impact the phenotypic characteristics and contribute to disorders like cancer, response to treatment, and infections. Four long-read aligners and five SV callers have been evaluated using three Oxford Nanopore NGS human genome datasets in terms of precision, recall, and F1-score statistical metrics, depth of coverage, and speed of analysis. The best SV caller regarding recall, precision, and F1-score when matched with different aligners at different coverage levels tend to vary depending on the dataset and the specific SV types being analyzed. However, based on our findings, Sniffles and CuteSV tend to perform well across different aligners and coverage levels, followed by SVIM, PBSV, and SVDSS in the last place. The CuteSV caller has the highest average F1-score (82.51%) and recall (78.50%), and Sniffles has the highest average precision value (94.33%). Minimap2 as an aligner and Sniffles as an SV caller act as a strong base for the pipeline of SV calling because of their high speed and reasonable accomplishment. PBSV has a lower average F1-score, precision, and recall and may generate more false positives and overlook some actual SVs. Our results are valuable in the comprehensive evaluation of popular SV callers and aligners as they provide insight into the performance of several long-read aligners and SV callers and serve as a reference for researchers in selecting the most suitable tools for SV detection.

Indexed as

Nanopore SequencingBenchmarkingGenomicsHumansMutationSequence AnalysisHuman genomeMutation detectionNanopore sequencingOxford nanopore technologyStructural variations (SVs)

Identifiers

PMID38486064
PMCPMC10940726
OpenAlexW4392812062

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.