Evidence map›Paper›PMID 38484201›Full record

ReviewAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2024

Design and Development of Transient Sensing Devices for Healthcare Applications.

Željko Janićijević, Tao Huang, Diana Isabel Sandoval Bojórquez, Taufhik Hossain Tonmoy, Salvador Pané, Denys Makarov, Larysa Baraban

Abstract readReview
In one paragraph

Review in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Design, Construction, and Application of Implantable Fiber Biosensors.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Designing for Degradation: Transient Devices Enabled by (Nano)Cellulose.Advanced materials (Deerfield Beach, Fla.) · 2025
    Review
  12. Review
  13. Review
  14. Article
  15. Bioresorbable electrodes in implantable electronic healthcare devices.Frontiers in bioengineering and biotechnology · 2025
    Review
  16. Review
  17. Review
  18. Article
  19. Design and Development of Transient Sensing Devices for Healthcare Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Željko JanićijevićInstitute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf e. V., 01328, Dresden, Germany.
Tao HuangInstitute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf e. V., 01328, Dresden, Germany.
Diana Isabel Sandoval BojórquezInstitute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf e. V., 01328, Dresden, Germany.
Taufhik Hossain TonmoyInstitute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf e. V., 01328, Dresden, Germany.
Salvador PanéMulti-Scale Robotics Lab (MSRL), Institute of Robotics & Intelligent Systems (IRIS), ETH Zürich, Zürich, 8092, Switzerland.
Denys MakarovInstitute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf e. V., 01328, Dresden, Germany.
Larysa BarabanInstitute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf e. V., 01328, Dresden, Germany.ORCID 0000-0003-1010-2791

Funding

European Research Council 101045415
6 · The paper itself

Abstract

With the ever-growing requirements in the healthcare sector aimed at personalized diagnostics and treatment, continuous and real-time monitoring of relevant parameters is gaining significant traction. In many applications, health status monitoring may be carried out by dedicated wearable or implantable sensing devices only within a defined period and followed by sensor removal without additional risks for the patient. At the same time, disposal of the increasing number of conventional portable electronic devices with short life cycles raises serious environmental concerns due to the dangerous accumulation of electronic and chemical waste. An attractive solution to address these complex and contradictory demands is offered by biodegradable sensing devices. Such devices may be able to perform required tests within a programmed period and then disappear by safe resorption in the body or harmless degradation in the environment. This work critically assesses the design and development concepts related to biodegradable and bioresorbable sensors for healthcare applications. Different aspects are comprehensively addressed, from fundamental material properties and sensing principles to application-tailored designs, fabrication techniques, and device implementations. The emerging approaches spanning the last 5 years are emphasized and a broad insight into the most important challenges and future perspectives of biodegradable sensors in healthcare are provided.

Indexed as

Equipment DesignBiosensing TechniquesDelivery of Health CareHumansMonitoring, PhysiologicWearable Electronic Devicesbiodegradable electronicsbiomedical devicesbiosensorsclinical diagnosticshealthcare applicationspoint‐of‐care diagnosticswearable electronics

Identifiers

PMID38484201
PMCPMC11132064

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.