Evidence map›Paper›PMID 38481928›Full record

ArticleCureus2024

Evaluation of the Stability of Internal Fixation Constructs in a Low Distal Tibia Extra-articular Cadaveric Fracture Model: A Comparative Biomechanical Study.

Tarkik Thami, Siddhartha Sharma, Amit Kumar, Naveen Kumar, Nitin Chauhan, Anjali Aggarwal, Mandeep Dhillon

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Tarkik ThamiOrthopaedics, Postgraduate Institute of Medical Education and Research, Chandigarh, Chandigarh, IND.
Siddhartha SharmaOrthopaedics, Postgraduate Institute of Medical Education and Research, Chandigarh, Chandigarh, IND.
Amit KumarMechanical Engineering, Indian Institute of Technology (IIT), Ropar, IND.
Naveen KumarMechanical Engineering, Indian Institute of Technology (IIT), Ropar, IND.
Nitin ChauhanOrthopaedics, All India Institute of Medical Sciences, New Delhi, New Delhi, IND.
Anjali AggarwalAnatomy, Postgraduate Institute of Medical Education and Research, Chandigarh, Chandigarh, IND.
Mandeep DhillonOrthopaedics, Postgraduate Institute of Medical Education and Research, Chandigarh, Chandigarh, IND.
Indian Institute of Technology Indore · INAll India Institute of Medical Sciences · INIndian Institute of Technology Ropar · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Despite the recent advances in implant design, the choice of an internal fixation modality for extra-articular distal tibia fractures remains controversial, and there is sparse literature comparing the stability of intramedullary nails and locked plates for such fractures. Hence, we conducted a biomechanical study on an AO type 43A3 tibia fracture cadaveric model stabilized by four different constructs, viz., intramedullary (IM) interlocking nail, anteromedial plate, anterolateral plate, and posterior plate. An AO type 43A3 fracture is defined as an extra-articular fracture of the distal tibia with metaphyseal comminution. Methods A biomechanical comparative study on formalin-preserved human cadaveric tibiae was undertaken; a total of four groups were tested, with eight bones in each group. Out of the 32 cadaveric tibiae, 19 bones belonged to male cadavers, and 13 bones belonged to female cadavers. All bones were dissected from age-appropriate cadavers and fixed with an implant, followed by the creation of a 1 cm osteotomy to simulate an AO type 43A3 fracture. All fixation constructs were subjected to three-point bending tests in the anteroposterior (AP) and mediolateral (ML) planes. Three parameters, viz., bending stiffness, peak fracture gap angle, and neutral zone, were evaluated on the load-displacement curves. A fixation construct was deemed biomechanically stable if it had a high bending stiffness, a low neutral zone (inherent toggle in the construct by its weight), and a low peak fracture gap angle. Results Out of the four implants tested, locked IM nails exhibited the maximum biomechanical stability in terms of higher bending stiffness, smaller peak fracture gap angle, and smaller neutral zones. The IM nail exhibited the highest bending stiffness in the AP plane, and the anterolateral plate had the lowest bending stiffness, and the difference was statistically significant (p= 0.032). In the AP plane, the anterolateral plate exhibited a bending stiffness of 1.51 ± 0.69 Nm/degree, whereas the intramedullary nail exhibited a bending stiffness of 2.34 ± 0.81 Nm/degree, and the posterior locked plate had a bending stiffness of 1.57 ± 0.44 Nm/degree. In the ML plane, the anterolateral plate exhibited the highest neutral zone as compared to the intramedullary nail, which had the lowest neutral zone, and the difference was statistically significant (p = 0.019). The intramedullary nail exhibited the lowest neutral zone of 0.46 ± 0.31 degrees, whereas the posterior locked plate exhibited a neutral zone of 0.78 ± 0.43 degrees in the ML plane. The anterolateral plate exhibited a neutral zone of 1.43 ± 1.00 (expressed as mean ± SD) degrees in the mediolateral plane. Conclusion Our biomechanical study supports the recommendations of using a locked intramedullary nail for AO type 43A3 fractures. We concluded that the anterolateral plate construct exhibited the least biomechanical stability, in terms of lower AP bending stiffness and higher neutral zone. If the surgeon must choose a locked plating technique for any reason, the anterolateral locking plate should be avoided. If plating is at all required, we can recommend both anteromedial and posterior locked plating as biomechanically sound options.

Indexed as

biomechanical studydistal tibiaextra-articular fracturesintramedullary nailinglocking compression plate

Identifiers

PMID38481928
PMCPMC10934011
OpenAlexW4391751521

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.