Evidence map›Paper›PMID 38481220›Full record

ArticleBMC oral health2024

A finite element analysis study on different angle correction designs for inclined implants in All-On-Four protocol.

Christine Raouf Micheal Ibrahim, Ahmed Sameh, Osama Askar

Open access · goldAbstract read
In one paragraph

Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
7.9field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Millisecond Laser Oblique Hole Processing of Alumina Ceramics.Nanomaterials (Basel, Switzerland) · 2025
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Christine Raouf Micheal IbrahimDepartment of Prosthodontics, Faculty of Dentistry, Mansoura University, Eldakahlia, Egypt. christineraouf@mans.edu.eg.
Ahmed SamehProduction Engineering and Mechanical Design Department, Faculty of Engineering, Mansoura University, Eldakahlia, Egypt.
Osama AskarDepartment of Prosthodontics, Faculty of Dentistry, Mansoura University, Eldakahlia, Egypt.
Mansoura University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this study is to investigate, through finite element analysis (FEA), the biomechanical behavior of the built-in angle corrected dental implant versus implant with angled multiunit abutment used in All-On-Four treatment protocol.

methodsTwo (3D) finite element models of a simplified edentulous mandible were constructed with two different posterior implant designs based on the All-On-Four protocol. Four implants were placed in each model, the two anterior implants were positioned vertically at the lateral incisor/canine sites. Depending on the implant fixture design in posterior area, there are two models created; Model I; the mandible was rehabilitated with four co-axis (4 mm in diameter × 15 mm in length) implants with distally built-in angle corrected implants (24-degree angle correction) .While Model II, the mandible was rehabilitated with four conventional (4 mm in diameter × 14 mm in length) implants with a distally inclined posterior implants (25 degree) and angled multiunit abutments. CAD software (Solidworks© 2017; Dassault Systems Solidworks Corp) was used to model the desired geometry. Axial and inclined Loads were applied on the two models. A Finite element analysis study was done using an efficient software ANSYS© with specified materials. The resultant equivalent Von-Misses stresses (VMS), maximum principal stresses and deformation analysis were calculated for each part (implants and prosthetic components).

resultsWhen applying axial and non-axial forces, model II (angled multiunit model) showed higher deformation on the level of Ti mesh about 13.286 μm and higher VMS 246.68 MPa than model I (angle corrected implant). Model I exhibited higher maximum stresses 107.83 MPa than Model II 94.988 MPa but the difference was not statistically significant.

conclusionWithin the limitation of the FEA study, although angle correcting implant design is showing higher values in maximum principle stresses compared with angled multiunit abutments, model deformation and resultant VMS increased with angled multiunit abutments. The angle correcting designs at implant level have more promising results in terms of deformation and VMS distribution than angle correction at abutment level.

Indexed as

Dental ImplantsComputer SimulationDental Prosthesis DesignDental Stress AnalysisFinite Element AnalysisHumansSoftwareStress, MechanicalDental ImplantsAngle corrected implantAngled multiunit abutmentFinite element analysis

Identifiers

PMID38481220
PMCPMC10938696
OpenAlexW4392747482

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked