ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2024
Efficacy of poller screw in addition to lag screw in the treatment of intertrochanteric fractures with proximal femoral nail: a biomechanical evaluation.
Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- The proximal femoral universal nail system (PFUN): a novel intramedullary nail for treating complex proximal femoral fractures and its biomechanical comparison with the proximal femoral nail anti-rotation (PFNA).Journal of orthopaedic surgery and research · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe most common type of failure in treating intertrochanteric fractures with proximal femoral nails is cut-out due to varus collapse. We aim to evaluate the effect of the poller screw applied to the proximal fragment and the lag screw on varus collapse and stability in intertrochanteric fractures.
methodsAn unstable intertrochanteric fracture model without medial support was simulated in 20 synthetic femur models. In the poller screw group, in addition to the lag screw, pole screws were applied to the proximal fragment superior and inferior to the lag screw. In the progressive cyclic loading test, starting from 100 N, the loading was increased by 50 N in each cycle, and the test was continued until the maximum load at which failure occurred as a result of conditioning cycles and progressive cyclic loading tests, stiffness, type of failure, force at failure, lag screw displacement, and varus collapse were recorded.
resultThe average stiffness was found to be 124.705 N/mm in the poller screw group and 102.77 N/mm in the control group (P < 0.001). The maximum load to failure was 1897.10 N in the poller screw group and 1475.20 N in the control group (P < 0.001). The average displacement of the lag screw within the femoral head was 0.85 mm in the poller screw group and 3.60 mm in the control group (P < 0.001).
conclusionAs a result, it has been shown that poller screws applied around the lag screw increase fixation stiffness and reduce varus collapse.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.