ArticleJournal of medical ultrasonics (2001)2024
Artifact reduction in photoacoustic images by generating virtual dense array sensor from hemispheric sparse array sensor using deep learning.
Article in Journal of medical ultrasonics (2001), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeVascular distribution is important information for diagnosing diseases and supporting surgery. Photoacoustic imaging is a technology that can image blood vessels noninvasively and with high resolution. In photoacoustic imaging, a hemispherical array sensor is especially suitable for measuring blood vessels running in various directions. However, as a hemispherical array sensor, a sparse array sensor is often used due to technical and cost issues, which causes artifacts in photoacoustic images. Therefore, in this study, we reduce these artifacts using deep learning technology to generate signals of virtual dense array sensors.
methodsGenerating 2D virtual array sensor signals using a 3D convolutional neural network (CNN) requires huge computational costs and is impractical. Therefore, we installed virtual sensors between the real sensors along the spiral pattern in three different directions and used a 2D CNN to generate signals of the virtual sensors in each direction. Then we reconstructed a photoacoustic image using the signals from both the real sensors and the virtual sensors.
resultsWe evaluated the proposed method using simulation data and human palm measurement data. We found that these artifacts were significantly reduced in the images reconstructed using the proposed method, while the artifacts were strong in the images obtained only from the real sensor signals.
conclusionUsing the proposed method, we were able to significantly reduce artifacts, and as a result, it became possible to recognize deep blood vessels. In addition, the processing time of the proposed method was sufficiently applicable to clinical measurement.