Evidence map›Paper›PMID 38478218›Full record

ArticleNeurochemical research2024

Negligible In Vitro Recovery of Macromolecules from Microdialysis Using 100 kDa Probes and Dextran in Perfusion Fluid.

Spille Dorothee, G Sørensen, L R Olsen, J F Bastlund, F Sotty, D Belling, M H Olsen, T I Mathiesen, K Møller, F Larsen and 1 more

Open access · hybridAbstract read
In one paragraph

Article in Neurochemical research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 3 countries.

Spille DorotheeDepartment of Neurosurgery, University Hospital Münster, Münster, Germany.
G SørensenH. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark.
L R OlsenH. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark.
J F BastlundH. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark.
F SottyH. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark.
D BellingH. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark.
M H OlsenDepartment of Clinical Medicine, Blegdamsvej 3, 2200, Copenhagen N, Denmark.
T I MathiesenDepartment of Neurosurgery, Rigshospitalet, Inge Lehmannsvej 6, 2100, Copenhagen Ø, Denmark.
K MøllerDepartment of Clinical Medicine, Blegdamsvej 3, 2200, Copenhagen N, Denmark.
F LarsenH. Lundbeck A/S, Ottiliavej 9, 2500, Copenhagen, Denmark.
P BirkelandDepartment of Neurosurgery, Rigshospitalet, Inge Lehmannsvej 6, 2100, Copenhagen Ø, Denmark. peter@birkeland.dk.
Lundbeck (Denmark) · DKRigshospitalet · DKUniversity Hospital Münster · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microdialysis is applied in neurointensive care to monitor cerebral glucose metabolism. If recoverable, macromolecules may also serve as biomarkers in brain disease and provide clues to their passage across the blood-brain barrier. Our study aimed to investigate the in vitro recovery of human micro- and macromolecules using microdialysis catheters and perfusion fluids approved for clinical use. In vitro microdialysis of a bulk solution containing physiological or supraphysiological concentrations of glucose, lactate, pyruvate, human IgG, serum albumin, and hemoglobin was performed using two different catheters and perfusion fluids. One had a membrane cut-off of 20 kDa and was used with a standard CNS perfusion fluid, and the other had a membrane cut-off of 100 kDa and was perfused with the same solution supplemented with dextran. The flow rate was 0.3 µl/min. We used both push and push-pull methods. Dialysate samples were collected at 2-h intervals for 6 h and analyzed for relative recovery of each substance. The mean relative recovery of glucose, pyruvate, and lactate was > 90% in all but two sets of experiments. In contrast, the relative recovery of human IgG, serum albumin, and hemoglobin from both bulk solutions was below the lower limit of quantification (LLOQ). Using a push-pull method, recovery of human IgG, serum albumin, and hemoglobin from a bulk solution with supraphysiological concentrations were above LLOQ but with low relative recovery (range 0.9%-1.6%). In summary, exchanging the microdialysis setup from a 20 kDa catheter with a standard perfusion fluid for a 100 kDa catheter with a perfusion solution containing dextran did not affect the relative recovery of glucose and its metabolites. However, it did not result in any useful recovery of the investigated macromolecules at physiological levels, either with or without a push-pull pump system.

Indexed as

Brain InjuriesDextransGlucoseHemoglobinsHumansImmunoglobulin GLactatesMicrodialysisPerfusionPyruvatesSerum AlbuminDextransGlucoseHemoglobinsImmunoglobulin GLactatesPyruvatesSerum AlbuminDextranIn vitroMacromoleculesMicrodialysis

Identifiers

PMID38478218
PMCPMC10991005
OpenAlexW4392763716

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.