Evidence map›Paper›PMID 38478088›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2025

Balloon technologies for pulmonary vein isolation-12-month outcome and comparison of the novel radiofrequency balloon with the cryoballoon in patients with paroxysmal atrial fibrillation.

Jan-Hendrik van den Bruck, Jonas Wörmann, Arian Sultan, Karlo Filipovic, Katharina Seuthe, Susanne Erlhöfer, Cornelia Scheurlen, Sebastian Dittrich, Jan-Hendrik Schipper, Jakob Lüker and 1 more

Abstract readComparative Study
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Jan-Hendrik van den BruckDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany. Jan-Hendrik.van-den-bruck@uk-koeln.de.ORCID http://orcid.org/0000-0003-0468-4887
Jonas WörmannDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.ORCID http://orcid.org/0000-0002-2213-8946
Arian SultanDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.ORCID http://orcid.org/0000-0003-1807-4860
Karlo FilipovicDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.
Katharina SeutheDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.ORCID http://orcid.org/0000-0002-6346-7500
Susanne ErlhöferDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.
Cornelia ScheurlenDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.ORCID http://orcid.org/0000-0001-7054-3535
Sebastian DittrichDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.
Jan-Hendrik SchipperDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.ORCID http://orcid.org/0000-0003-0208-3295
Jakob LükerDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.ORCID http://orcid.org/0000-0003-4667-2200
Daniel StevenDepartment of Electrophysiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany.ORCID http://orcid.org/0000-0001-6839-5895

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe cryoballoon (CB) has become a standard tool for pulmonary vein isolation (PVI), but the technology is limited in certain ways. A novel RF-balloon (Heliostar™, Biosense Webster, CA, USA) promises the advantages of a balloon technology in combination with 3D mapping.

methodsTo assess procedural data and outcome, all patients undergoing RF-balloon PVI were included and compared with data from consecutive patients undergoing CB PVI for paroxysmal AF.

resultsA total of 254 patients (63 ± 13 years, 54% male) were included: 30 patients undergoing RF-balloon and 224 patients CB PVI. Baseline parameters were comparable. Procedure duration (104.3 ± 35.3 min vs. 69.9 ± 23.1 min; p ≤ 0.001) and fluoroscopy time (16.3 ± 7.1 min vs. 11.6 ± 4.9 min; p ≤ 0.001) were longer using the RF-balloon; ablation time (43.5 ± 17.9 vs. 36.4 ± 15.6; p = 0.08) did not differ, and time-to-isolation (TTI) was shorter (18.2 ± 7.0 s vs. 62.8 ± 35.1 s; p ≤ 0.001). Second-generation RF-balloon cases showed shorter ablation time and TTI at comparable procedure duration and fluoroscopy time. One pericardial effusion occurred with the RF-balloon due to complicated transseptal access. During CB PVI in 4/224 patients (1.8%), a phrenic nerve palsy was observed. After 12 months, 78% of patients after RF-balloon and 81% of patients after CB PVI (p = 0.5) were free from atrial arrhythmias.

conclusionThe RF-balloon was safe and effective. Compared with the CB, TTI was shorter, but procedure durations and fluoroscopy times were longer. This can be attributed to a learning curve and the initial necessity for separate 3D map preparation. Considering the results with the second-generation RF-balloon, more experience is needed to determine the potential benefits.

Indexed as

Atrial FibrillationCatheter AblationCryosurgeryPulmonary VeinsAgedEquipment DesignFemaleFluoroscopyFollow-Up StudiesHumansMaleMiddle AgedOperative TimeRetrospective StudiesTime FactorsTreatment OutcomeAtrial fibrillationCryoballoon ablationHeliostar™Radiofrequency balloonSingle shot pulmonary vein isolation

Identifiers

PMID38478088
PMCPMC11772379

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.