Cost-Effectiveness of Inpatient Continuous Glucose Monitoring.

David Veríssimo, Beatriz R Pereira, Joana Vinhais, Catarina Ivo, Ana C Martins, João N Silva, Dolores Passos, Luís Lopes, João Jácome de Castro, Mafalda Marcelino

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

David VeríssimoDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
Beatriz R PereiraDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
Joana VinhaisDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
Catarina IvoDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
Ana C MartinsDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
João N SilvaDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
Dolores PassosDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
Luís LopesDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
João Jácome de CastroDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
Mafalda MarcelinoDepartment of Endocrinology, Hospital das Forças Armadas, Lisbon, PRT.
Hospital Central de las Fuerzas Armadas · UYHospital das Forças ArmadasArmada (Poland) · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Our department conducted a retrospective cohort study to compare the efficacy of continuous glucose monitoring devices versus capillary blood glucose in the glycemic control of inpatient type 2 diabetes on intensive insulin therapy in a Portuguese hospital. The use of continuous glucose monitoring devices was associated with improved glycemic control, including an increased number of glucose readings within target range and reduced hyperglycemic events, being safe concerning hypoglycemias. This is the cost-effectiveness analysis associated with these results. Aim The primary objective was to compare the cost-effectiveness of achieving glycemic control, defined as the number of patients within glycemic goals, between groups. Secondary endpoints included cost-effectiveness analyses of each time in range goal, and each percentual increment in time in range. Methods We defined each glycemic goal as: "readings within range (70-180 mg/dL) >70%", "readings below range (below 70 mg/dL) <4%", "severe hypoglycemia (below 54 mg/dL) <1%", "readings above range (above 180 mg/dL) <25%", "very high glycemic readings (above 250 mg/dL) <5%". Results Continuous glucose monitoring showed lower median cost per effect for the primary outcome (€11.1 vs. €34.9/patient), with lower cost for readings in range (€7.8 vs. €11.6/patient) and for both readings above range goals ("above 180mg/dL": €7.4 vs. €9.9/patient, and "above 250mg/dL": €6.9 vs. €17.4/patient). Conclusions There are no published data regarding the cost-effectiveness of continuous glucose monitoring devices in inpatient settings. Our results show that continuous glucose monitoring devices were associated with an improved glycemic control, at a lower cost, and endorse the feasibility of incorporating these devices into hospital settings, presenting a favorable cost-effective option compared to capillary blood glucose.

Indexed as

continuous glucose monitoringcost-effectivenesshospitalized patientsportugaltype 2 diabetes

Identifiers

PMID38476508
PMCPMC10928466
OpenAlexW4392711208

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.