Evidence map›Paper›PMID 38475917›Full record

ArticleJournal of orthopaedic surgery and research2024

Time-elapsed microstructural imaging of failure of the reverse shoulder implant.

Saulo Martelli, Egon Perilli, Xiaolong Fan, Sophie Rapagna, Ashish Gupta

Open access · goldAbstract readCase Reports
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.6field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Saulo MartelliSchool of Mechanical Medical and Process Engineering, Queensland University of Technology, Gardens Point Campus, P'Block, Level 7, Room 717, Brisbane, QLD, 4000, Australia. saulo.martelli@qut.edu.au.
Egon PerilliMedical Devices Research Institute, College of Science and Engineering, Flinders University, Adelaide, SA, Australia.
Xiaolong FanSchool of Mechanical Medical and Process Engineering, Queensland University of Technology, Gardens Point Campus, P'Block, Level 7, Room 717, Brisbane, QLD, 4000, Australia.
Sophie RapagnaMedical Devices Research Institute, College of Science and Engineering, Flinders University, Adelaide, SA, Australia.
Ashish GuptaGreenslopes Private Hospital, Brisbane, QLD, Australia.
Queensland University of Technology · AUFlinders University · AU

Funding

Australian Research Council FT180100338Australian Research Council IC190100020
6 · The paper itself

Abstract

backgroundReverse Shoulder Arthroplasties (RSA) have become a primary choice for improving shoulder function and pain. However, the biomechanical failure mechanism of the humeral component is still unclear. The present study reports a novel protocol for microstructural imaging of the entire humerus implant under load before and after fracture.

methodsA humerus specimen was obtained from a 75-year-old male donor. An expert surgeon implanted the specimen with a commonly used RSA implant (Aequalis reversed II, Stryker Orthopaedics, USA) and surgical procedure. The physiological glenohumeral contact force that maximized the distal implant migration was selected from a public repository ( orthoload.com ). Imaging and concomitant mechanical testing were performed using a large-volume micro-CT scanner (Nikon XT H 225 ST) and a custom-made compressive stage. Both when intact and once implanted, the specimen was tested under a pre-load and by imposing a constant deformation causing a physiological reaction load (650 N, 10 degrees adducted). The deformation of the implanted specimen was then increased up to fracture, which was identified by a sudden drop of the reaction force, and the specimen was then re-scanned.

resultsThe specimen's stiffness decreased from 874 N/mm to 464 N/mm after implantation, producing movements of the bone-implant interface consistent with the implant's long-term stability reported in the literature. The micro-CT images displayed fracture of the tuberosity, caused by a combined compression and circumferential tension, induced by the distal migration of the implant.

conclusionThe developed protocol offers detailed information on implant mechanics under load relative to intact conditions and fracture, providing insights into the failure mechanics of RSA implants. This protocol can be used to inform future implant design and surgical technique improvements.

Indexed as

Fractures, BoneShoulder JointAgedHumansHumerusMaleProsthesis DesignRange of Motion, ArticularShoulderUpper ExtremityBiomechanicsBone microstructural imagingImplant failureReverse shoulder arthroplasty

Identifiers

PMID38475917
PMCPMC10935865
OpenAlexW4392699807

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.