ArticleEuropean journal of medical research2024
Increasing the angle between caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture.
Article in European journal of medical research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.
- Effect of different types of internal fixation on the incidence of femoral head necrosis in adult femoral neck fractures: a single-arm rate and network meta-analysis.European journal of medical research · 2025Pooled it
- Value of CT in quantitatively diagnosing and assessing collapse in patients with femoral head necrosis based on finite element mechanics analysis.BMC musculoskeletal disorders · 2026Article
- Oxidative stress biomarkers and chondrocyte apoptosis as predictors of postoperative outcomes in osteonecrosis of the femoral head.Journal of medical biochemistry · 2026Article
- Wider screw spread can reduce the risk of short-term femoral head necrosis by optimizing the fixation stability in femoral neck fracture patients with triangle cannulated screw fixation.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Article
- Changes in facet orientation may simultaneously affect the potential risk of annulus tears and zygapophyseal joint osteoarthritis: a clinical review and biomechanical simulation.La Radiologia medica · 2025Article
- Larger nail-shaft gap as a potential risk factor of femoral head varus in patients treated with proximal femoral nail antirotation fixation: a retrospective, observational, single-center study with corresponding numerical simulation.Quantitative imaging in medicine and surgery · 2025Article
- The ratio between the screw distance and femoral neck width on lateral radiography is a reliable predictor of femoral head necrosis: a clinical review and corresponding numerical simulations.Journal of orthopaedic surgery and research · 2024Article
- Biomechanical characteristic differences of two new types of intramedullary nail devices in the treatment of comminuted intertrochanteric fractures of femur: a comparative study based on finite element analysis.Journal of orthopaedic surgery and research · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Necrosis of the femoral head is the main complication in femoral neck fracture patients with triangle cannulated screw fixation. Instant postoperative fixation instability is a main reason for the higher risk of femoral head necrosis. Biomechanical studies have shown that cross screw fixation can effectively optimize fixation stability in patients with proximal humerus fractures and pedicle screw fixation, but whether this method can also effectively optimize the fixation stability of femoral neck fractures and reduce the corresponding risk of femoral head necrosis has yet to be identified. In this study, a retrospective review of imaging data in femoral neck fracture patients was performed. The cross angle between the femoral neck and the caudal cannulated screw was reported; if the angle between the screw and the transverse plane increased, it was recorded as positive; otherwise, it was recorded as negative. Angle values and their corresponding absolute values were compared in patients with and without femoral head necrosis. Regression analysis identified potential risk factors for femoral head necrosis. Moreover, the biomechanical effect of the screw-femoral neck angle on fixation stability was also verified by numerical mechanical simulations. Clinical review presented significantly larger positive angle values in patients with femoral head necrosis, which was also proven to be an independent risk factor for this complication. Moreover, fixation stability progressively deteriorated with increasing angle between the caudal screw and the transverse plane. Therefore, increasing the angle between the caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.