Abstract read
In one paragraph

Article in Polymers, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Study of TiOMaterials (Basel, Switzerland) · 2026
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Evgenii M Shcherban'Department of Engineering Geology, Bases, and Foundations, Don State Technical University, 344003 Rostov-on-Don, Russia.ORCID 0000-0001-5376-247X
Sergey A Stel'makhDepartment of Unique Buildings and Constructions Engineering, Don State Technical University, 344003 Rostov-on-Don, Russia.ORCID 0000-0002-0364-5504
Levon R MailyanDepartment of Unique Buildings and Constructions Engineering, Don State Technical University, 344003 Rostov-on-Don, Russia.
Alexey N BeskopylnyDepartment of Transport Systems, Faculty of Roads and Transport Systems, Don State Technical University, 344003 Rostov-on-Don, Russia.ORCID 0000-0002-6173-9365
Alla S SmolyanichenkoDepartment of Water Supply and Sewerage, Don State Technical University, 344003 Rostov-on-Don, Russia.
Andrei Chernil'nikDepartment of Unique Buildings and Constructions Engineering, Don State Technical University, 344003 Rostov-on-Don, Russia.ORCID 0000-0002-0103-2587
Diana ElshaevaDepartment of Unique Buildings and Constructions Engineering, Don State Technical University, 344003 Rostov-on-Don, Russia.
Nikita BeskopylnyDepartment Hardware and Software Engineering, Don State Technical University, 344003 Rostov-on-Don, Russia.

Funding

Russian Science Foundation 23-79-10289
6 · The paper itself

Abstract

The application of polymer materials in concrete structures is widespread and effectively used. However, there is a lack of a systematic knowledge base about the structure formation and properties of variatropic vibrocentrifuged modified fiber-reinforced concrete. The purpose of this work is the investigation of the influence of polypropylene (PF) and basalt fiber (BF) and modification with microsilica (MS) on the properties of variatropic concretes obtained using the synthesized vibration centrifugation technology. Test samples were made using vibration centrifugation technology, followed by sawing. Various types of fiber reinforcement were studied, both individually and in combination. To determine the degree of effectiveness of each recipe solution, the following main characteristics were monitored: the density and workability of concrete mixtures; the density of hardened composites; compressive strength (CS); bending strength (BS); water absorption (WA). In variatropic vibrocentrifuged concrete, the greatest efficiency is achieved with dispersed BF reinforcement in an amount of 1.5%. Compared to the control composition, the increase in CS was 8.50%, the increase in BS was 79.17%, and WA decreased by 27.54%. With PF reinforcement, the greatest effect was recorded at a dosage of 1.0%. The increase in CS was 3.16%, the increase in BS was 10.42%, and WA decreased by 17.39%. The MS modification showed the best effect with 8% replacement of part of the Portland cement. The increase in CS was 17.43%, the increase in BS was 14.58%, and WA decreased by 33.30%. The most effective and economically rational formulation solution for vibrocentrifuged concrete is combined fiber reinforcement in combination with the MS modification in the following quantities: BF-1.0%; PF-0.5%; MS-8%. The increase in CS was 22.82%, the increase in BS was 85.42%, and WA decreased by 37.68%.

Indexed as

concrete modificationfiber concretepolymer fiberpolymersvariatropic concretevibrocentrifuged concrete