Evidence map›Paper›PMID 38475199›Full record

ArticleSensors (Basel, Switzerland)2024

COVID-Net L2C-ULTRA: An Explainable Linear-Convex Ultrasound Augmentation Learning Framework to Improve COVID-19 Assessment and Monitoring.

E Zhixuan Zeng, Ashkan Ebadi, Adrian Florea, Alexander Wong

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. AI-Enhanced POCUS in Emergency Care.Diagnostics (Basel, Switzerland) · 2026
    Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

E Zhixuan ZengDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.ORCID 0000-0002-8034-596X
Ashkan EbadiDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.ORCID 0000-0002-4542-9105
Adrian FloreaDepartment of Emergency Medicine, McGill University, Montreal, QC H4A 3J1, Canada.
Alexander WongDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

While no longer a public health emergency of international concern, COVID-19 remains an established and ongoing global health threat. As the global population continues to face significant negative impacts of the pandemic, there has been an increased usage of point-of-care ultrasound (POCUS) imaging as a low-cost, portable, and effective modality of choice in the COVID-19 clinical workflow. A major barrier to the widespread adoption of POCUS in the COVID-19 clinical workflow is the scarcity of expert clinicians who can interpret POCUS examinations, leading to considerable interest in artificial intelligence-driven clinical decision support systems to tackle this challenge. A major challenge to building deep neural networks for COVID-19 screening using POCUS is the heterogeneity in the types of probes used to capture ultrasound images (e.g., convex vs. linear probes), which can lead to very different visual appearances. In this study, we propose an analytic framework for COVID-19 assessment able to consume ultrasound images captured by linear and convex probes. We analyze the impact of leveraging extended linear-convex ultrasound augmentation learning on producing enhanced deep neural networks for COVID-19 assessment, where we conduct data augmentation on convex probe data alongside linear probe data that have been transformed to better resemble convex probe data. The proposed explainable framework, called COVID-Net L2C-ULTRA, employs an efficient deep columnar anti-aliased convolutional neural network designed via a machine-driven design exploration strategy. Our experimental results confirm that the proposed extended linear-convex ultrasound augmentation learning significantly increases performance, with a gain of 3.9% in test accuracy and 3.2% in AUC, 10.9% in recall, and 4.4% in precision. The proposed method also demonstrates a much more effective utilization of linear probe images through a 5.1% performance improvement in recall when such images are added to the training dataset, while all other methods show a decrease in recall when trained on the combined linear-convex dataset. We further verify the validity of the model by assessing what the network considers to be the critical regions of an image with our contribution clinician.

Indexed as

COVID-19Decision Support Systems, ClinicalArtificial IntelligenceHumansLearningUltrasonographyCOVID-19 assessmentdeep explainable architecturelinear–convex augmentationlung ultrasonic imaging

Identifiers

PMID38475199
PMCPMC10933837

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.