Evidence map›Paper›PMID 38474895›Full record

ArticleSensors (Basel, Switzerland)2024

Diagnostics of Internal Defects in Composite Overhead Insulators Using an Optic E-Field Sensor.

Damiano Fasani, Luca Barbieri, Andrea Villa, Daniele Palladini, Roberto Malgesini, Giovanni D'Avanzo, Giacomo Buccella, Paolo Gadia

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Damiano FasaniRSE SpA-Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy.
Luca BarbieriRSE SpA-Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy.ORCID 0000-0001-7296-9169
Andrea VillaRSE SpA-Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy.ORCID 0000-0002-3282-945X
Daniele PalladiniRSE SpA-Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy.ORCID 0000-0002-4293-1925
Roberto MalgesiniRSE SpA-Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy.
Giovanni D'AvanzoRSE SpA-Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy.ORCID 0000-0001-9361-8309
Giacomo BuccellaRSE SpA-Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy.
Paolo GadiaRSE SpA-Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy.
Ricerca sul Sistema Energetico (Italy) · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Composite insulators for high-voltage overhead lines have better performances and are lighter than traditional designs, especially in heavily polluted areas. However, since it is a relatively recent technology, reliable methods to perform live-line diagnostics are still under development, especially with regard to internal defects, which provide few external symptoms. Thermal cameras can be employed, but their use is not always straightforward as the sun radiation can hide the thermal footprint of internal degenerative effects. In this work, an optical E-field sensor has been used to diagnose the internal defects of a set of composite insulators (bandwidth 200 mHz-50 MHz, min. detectable E-field 100 V/m). Moreover, a modelling activity using finite elements has been carried out to identify the possible nature of the defects by comparing experimental E-field profiles with those simulated assuming a specific defect geometry. The results show that the sensor can detect the presence of an internal defect, since its presence distorts the E-field profile when compared to the profile of a sound insulator. Moreover, the measured E-field profiles are compatible with the corresponding simulated ones when a conductive defect is considered. However, it was observed that a defect whose conductivity is not at least two orders of magnitude greater than the conductivity of the surroundings remains undetected.

Indexed as

composite insulatorelectro-optic sensorlive-line diagnostics

Identifiers

PMID38474895
PMCPMC10934223
OpenAlexW4391956958

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.