Evidence map›Paper›PMID 38473040›Full record

ArticleDiagnostics (Basel, Switzerland)2024

Deep Convolutional Neural Networks Provide Motion Grading for High-Resolution Peripheral Quantitative Computed Tomography of the Scaphoid.

Stefan Benedikt, Philipp Zelger, Lukas Horling, Kerstin Stock, Johannes Pallua, Michael Schirmer, Gerald Degenhart, Alexander Ruzicka, Rohit Arora

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 2 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Stefan BenediktDepartment of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.ORCID 0000-0001-6696-6519
Philipp ZelgerDepartment of Otorhinolaryngology, Hearing, Speech & Voice Disorders, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.ORCID 0000-0002-6543-7620
Lukas HorlingDepartment of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.
Kerstin StockDepartment of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.ORCID 0000-0003-2417-0824
Johannes PalluaDepartment of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.ORCID 0000-0003-0203-213X
Michael SchirmerMedical University of Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.ORCID 0000-0001-9208-7809
Gerald DegenhartDepartment of Radiology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.ORCID 0000-0002-9961-1084
Alexander RuzickaDepartment of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.ORCID 0000-0001-9160-9572
Rohit AroraDepartment of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.
University Hospital Innsbruck · ATInnsbruck Medical University · AT

Funding

Johnson & Johnson Medical Products GmbH GMAFS20353
6 · The paper itself

Abstract

In vivo high-resolution peripheral quantitative computed tomography (HR-pQCT) studies on bone characteristics are limited, partly due to the lack of standardized and objective techniques to describe motion artifacts responsible for lower-quality images. This study investigates the ability of such deep-learning techniques to assess image quality in HR-pQCT datasets of human scaphoids. In total, 1451 stacks of 482 scaphoid images from 53 patients, each with up to six follow-ups within one year, and each with one non-displaced fractured and one contralateral intact scaphoid, were independently graded by three observers using a visual grading scale for motion artifacts. A 3D-CNN was used to assess image quality. The accuracy of the 3D-CNN to assess the image quality compared to the mean results of three skilled operators was between 92% and 96%. The 3D-CNN classifier reached an ROC-AUC score of 0.94. The average assessment time for one scaphoid was 2.5 s. This study demonstrates that a deep-learning approach for rating radiological image quality provides objective assessments of motion grading for the scaphoid with a high accuracy and a short assessment time. In the future, such a 3D-CNN approach can be used as a resource-saving and cost-effective tool to classify the image quality of HR-pQCT datasets in a reliable, reproducible and objective way.

Indexed as

artifactsartificial intelligenceconvolutional neural networksdeep learningimage qualitymotion grading

Identifiers

PMID38473040
PMCPMC10931275
OpenAlexW4392549902

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.