ArticleClinical orthopaedics and related research2024
Microwave Ablation of the Pig Growth Plate: Proof of Concept for Minimally Invasive Epiphysiodesis.
Article in Clinical orthopaedics and related research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- Physeal Allograft Transfer for Physeal Bars: A Safety and Feasibility Study in a Domestic Swine Model.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026Article
- Use of digital image analysis to improve rigor and efficiency of physeal bone growth measurements.Histology and histopathology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 1 country.
Funding
Abstract
backgroundDifferent surgical methods for epiphysiodesis of limb length discrepancy (LLD) have been described. Although these methods are variably effective, they are associated with morbidity (pain and limp) and potential complications. Microwave ablation is a less-invasive opportunity to halt growth by selectively destroying the growth plate via thermal energy to treat LLD in children. QUESTIONS/PURPOSES: In this proof-of-concept study using an in vivo pig model, we asked: (1) What is the durability of response 2 to 4 months after microwave ablation of the tibial growth plate as measured by length and angulation of the tibia via a CT scan? (2) Was articular cartilage maintained as measured by standard histologic staining for articular cartilage viability?
methodsTo develop an in vivo protocol for microwave ablation, we placed microwave antennas adjacent to the proximal tibia growth plate in the cadaveric hindlimbs of 18 3-month-old pigs. To determine the suitable time, we varied ablation from 90 to 270 seconds at 65-W power settings. After sectioning the tibia, we visually assessed for discoloration (implying growth plate destruction) that included the central growth plate but did not encroach into the epiphysis in a manner that could disrupt the articular surface. Using this information, we then performed microwave ablation on three live female pigs (3.5 to 4 months old) to evaluate physiologic changes and durability of response. A postprocedure MRI was performed to ensure the intervention led to spatial growth plate alterations similar to that seen in cadavers. This was followed by serial CT, which was used to assess the potential effect on local bone and growth until the animals were euthanized 2 to 4 months after the procedure. We analyzed LLD, angular deformity, and bony deformity using CT scans of both tibias. The visibility of articular cartilage was compared with that of the contralateral tibia via standard histologic staining, and growth rates of the proximal tibial growth plate were compared via fluorochrome labeling.
resultsEighteen cadaveric specimens showed ablation zones across the growth plate without visual damage to the articular surface. The three live pigs did not exhibit changes in gait or require notable pain medication after the procedure. Each animal demonstrated growth plate destruction, expected limb shortening (0.8, 1.2, and 1.5 cm), and bony cavitation around the growth plate. Slight valgus bone angulation (4º, 5º, and 12º) compared with the control tibia was noted. No qualitatively observable articular cartilage damage was encountered from the histologic comparison with the contralateral tibia for articular cartilage thickness and cellular morphology.
conclusionA microwave antenna placed into a pig's proximal tibia growth plate can slow the growth of the tibia without apparent pain and alteration of gait and function. CLINICAL RELEVANCE: Further investigation and refinement of our animal model is ongoing and includes shorter ablation times and comparison of dynamic ablation (moving the antennae during the ablation) as well as static ablation of the tibia from a medial and lateral portal. These refinements and planned comparison with standard mechanical growth arrest in our pig model may lead to a similar approach to ablate growth plates in children with LLD.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.