ArticlePLOS global public health2024
Validation of ToucHb, a non-invasive haemoglobin estimation: Effective for normal ranges, needs improvement for anaemia detection.
Article in PLOS global public health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Article
- Article
- Correction: Validation of ToucHb, a non-invasive haemoglobin estimation: Effective for normal ranges, needs improvement for anaemia detection.PLOS global public health · 2024Article
Corrections and comments
- Erratum issued
Authors and funding
4 authors.
Funding
Abstract
Non-invasive methods for haemoglobin estimation hold enormous potential for early detection and treatment of anaemia, especially in limited resource settings. We sought to validate the diagnostic accuracy of ToucHb, a non-invasive haemoglobin estimation device available in the Indian market. We prospectively evaluated the diagnostic performance of the ToucHb device using the Automated complete blood count (CBC) method as the gold standard. Persons referred for haemoglobin estimation to the central laboratory of the government medical college hospital in Mysore, southern India were included in the study. Out Of 140 people approached, 127 gave consent; 65% (n = 82) were female with median age of 37 (IQR 28-45). ToucHB reported median haemoglobin value of 14 g/dL compared to 13.3 g/dL for CBC. Within 1 g/dL and 2 g/dL of CBC, 55.2% (70/127) and 74% (94/127) of ToucHb haemoglobin observations fell, respectively. The Bland-Altman plot showed a mean difference of 3 g/dL in haemoglobin between ToucHb and CBC among those with anaemia. The ToucHb device showed 22.2% sensitivity and 94.5% specificity for anaemia detection. In rural resource-limited settings, point of care non-invasive devices such as ToucHb can improve access and acceptance for anaemia screening. However, ToucHb has showed low sensitivity for anaemia detection and low accuracy at lower haemoglobin values. The utility of the instrument is especially limited in detecting anaemia, while it can estimate haemoglobin accurately among those with haemoglobin is in the normal range. Based on these findings, ToucHb and devices that work on the core technology deployed in ToucHb may be better suited to monitor known haemoglobin level rather than in anaemia screening or detection in primary/ secondary care and community settings.