Evidence map›Paper›PMID 38469944›Full record

ArticleMagnetic resonance in medicine2024

Inline automatic quality control of 2D phase-contrast flow MRI for subject-specific scan time adaptation.

Pierre Daudé, Rajiv Ramasawmy, Ahsan Javed, Robert J Lederman, Kelvin Chow, Adrienne E Campbell-Washburn

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pierre DaudéLaboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.ORCID 0000-0002-0565-8974
Rajiv RamasawmyLaboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.ORCID 0000-0002-9821-9187
Ahsan JavedLaboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.ORCID 0000-0003-1311-1247
Robert J LedermanLaboratory of Cardiovascular Intervention, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.ORCID 0000-0003-1202-6673
Kelvin ChowSiemens Healthcare Ltd., Calgary, Alberta, Canada.ORCID 0000-0003-0698-1746
Adrienne E Campbell-WashburnLaboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.ORCID 0000-0002-7169-5693

Funding

Real-time MRI guided cardiovascular interventionZIAHL005062 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2009 to 2025
$21.6M
Real-time cardiovascular MRI and co-registration technical developmentZIAHL006039 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2010 to 2024
$10.3M
Development of high-performance low field MRI technology ZIAHL006257 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI CAMPBELL-WASHBURN, ADRIENNE · 2021 to 2025
$8.1M
Innovative Technology for MRI Guided ProceduresZIAHL006213 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI CAMPBELL-WASHBURN, ADRIENNE · 2016 to 2025
$5.4M
Intramural NIH HHS ZIA HL006213Intramural NIH HHS ZIA HL006257NHLBI Division of Intramural Research ZIA-HL006213NHLBI Division of Intramural Research ZIA-HL006257
6 · The paper itself

Abstract

purposeTo develop an inline automatic quality control to achieve consistent diagnostic image quality with subject-specific scan time, and to demonstrate this method for 2D phase-contrast flow MRI to reach a predetermined SNR.

methodsWe designed a closed-loop feedback framework between image reconstruction and data acquisition to intermittently check SNR (every 20 s) and automatically stop the acquisition when a target SNR is achieved. A free-breathing 2D pseudo-golden-angle spiral phase-contrast sequence was modified to listen for image-quality messages from the reconstructions. Ten healthy volunteers and 1 patient were imaged at 0.55 T. Target SNR was selected based on retrospective analysis of cardiac output error, and performance of the automatic SNR-driven "stop" was assessed inline.

resultsSNR calculation and automated segmentation was feasible within 20 s with inline deployment. The SNR-driven acquisition time was 2 min 39 s ± 67 s (aorta) and 3 min ± 80 s (main pulmonary artery) with a min/max acquisition time of 1 min 43 s/4 min 52 s (aorta) and 1 min 43 s/5 min 50 s (main pulmonary artery) across 6 healthy volunteers, while ensuring a diagnostic measurement with relative absolute error in quantitative flow measurement lower than 2.1% (aorta) and 6.3% (main pulmonary artery).

conclusionThe inline quality control enables subject-specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject-specific scan time.

Indexed as

Image Processing, Computer-AssistedMagnetic Resonance ImagingQuality ControlSignal-To-Noise RatioAdultAlgorithmsAortaFemaleHealthy VolunteersHumansImage Interpretation, Computer-AssistedMalePulmonary ArteryReproducibility of ResultsRespirationRetrospective Studiesinline processingphase contrast flowquality assessmentscan time

Identifiers

PMID38469944
PMCPMC11142871

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.