Evidence map›Paper›PMID 38469026›Full record

ArticleCureus2024

Experimental Study of Failures of the Rigid Spinal Posterior Fixation System Under Compressive Load Conditions: A Cadaver Study.

Takaya Kato, Tadashi Inaba, Sotaro Baba, Tadatsugu Morimoto, Tetsutaro Mizuno, Yuichi Kasai, Taweechok Wisanuyotin, Winai Sirichativapee, Weerachai Kosuwon, Permsak Paholpak

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 98% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Takaya KatoDepartment of Social Innovation, Graduate School of Regional Innovation Studies, Mie University, Tsu, JPN.
Tadashi InabaDepartment of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, JPN.
Sotaro BabaDepartment of Mechanical Engineering, Graduate School of Engineering, Mie University, Tsu, JPN.
Tadatsugu MorimotoDepartment of Orthopaedic Surgery, Faculty of Medicine, Saga University, Saga, JPN.
Tetsutaro MizunoDepartment of Orthopaedic Surgery, Seirei Hamamatsu General Hospital, Hamamatsu, JPN.
Yuichi KasaiDepartment of Orthopaedics, Faculty of Medicine, Khon Kaen University, Khon Kaen, THA.
Taweechok WisanuyotinDepartment of Orthopaedics, Faculty of Medicine, Khon Kaen University, Khon Kaen, THA.
Winai SirichativapeeDepartment of Orthopaedics, Faculty of Medicine, Khon Kaen University, Khon Kaen, THA.
Weerachai KosuwonDepartment of Orthopaedics, Faculty of Medicine, Khon Kaen University, Khon Kaen, THA.
Permsak PaholpakDepartment of Orthopaedics, Faculty of Medicine, Khon Kaen University, Khon Kaen, THA.
Seirei Hamamatsu General Hospital · JPKhon Kaen University · THMie University · JPSaga University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Many studies have been conducted on the biomechanics of the spine to elucidate the fixation properties of spinal fusion surgery and the causes of instrumentation failure. Among these studies, there are some studies on load sharing in the spine and measurement using strain gauges and pressure gauges, but there is a lack of research on axial compressive loads. Methods Axial compressive load tests were performed on human cadaveric injured lumbar vertebrae fixed with pedicle screws (PS). Both the strain generated in the PS rod and the intradiscal pressure were measured. Subsequently, the stress generated in the PS rod and the load sharing of the spine and instrumentation were calculated. Results Even when only compressive load is applied, bending stress of more than 10 times the compression stress was generated in the rod, and the stress tended to concentrate on one rod. Rod deformation becomes kyphotic, in contrast to the lordotic deformation behavior of the lumbar spine. The stress shielding rate was approximately 40%, less than half. Conclusions This study obtained basic data useful for constructing and verifying numerical simulations that are effective for predicting and elucidating the causes of dislodgement and failure of spinal implants.

Indexed as

biomechanicshuman cadaver experimentinstrumentation failureintradiscal pressurelumbar spinesimulation modelsspinal instrumentationstrain

Identifiers

PMID38469026
PMCPMC10925939
OpenAlexW4391719574

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked