Evidence map›Paper›PMID 38468329›Full record

ArticleChinese neurosurgical journal2024

Evaluation of the EMBOPIPE flow diverter device: in vivo and in vitro experiments.

Yongnan Zhu, Fanyan Zeng, Jian Liu, Shiqing Mu, Ying Zhang, Xinjian Yang

Erratum issuedOpen access · diamondAbstract read
In one paragraph

Article in Chinese neurosurgical journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Yongnan ZhuDepartment of Beijing Neurosurgical Institute, Fengtai District, Capital Medical University, No. 119, South Fourth Ring West Road, Beijing, 100070, People's Republic of China.
Fanyan ZengFengxian District, Heartcare Medical Technology Co., Ltd, Building 38, No. 356 Zhengbo Road, Shanghai, 200000, People's Republic of China.
Jian LiuNeurosurgical Institute & Department of Neurosurgery, Fengtai District, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring West Road, Beijing, 100070, People's Republic of China.
Shiqing MuNeurosurgical Institute & Department of Neurosurgery, Fengtai District, Beijing Tiantan Hospital, Capital Medical University, No. 119, South Fourth Ring West Road, Beijing, 100070, People's Republic of China.
Ying ZhangDepartment of Beijing Neurosurgical Institute, Fengtai District, Capital Medical University, No. 119, South Fourth Ring West Road, Beijing, 100070, People's Republic of China. yingzhang829@163.com.ORCID http://orcid.org/0000-0002-5812-372X
Xinjian YangDepartment of Beijing Neurosurgical Institute, Fengtai District, Capital Medical University, No. 119, South Fourth Ring West Road, Beijing, 100070, People's Republic of China. yangxinjian@voiceoftiantan.org.
Capital Medical University · CNBeijing Institute of Neurosurgery · CNBeijing Tian Tan Hospital · CN

Funding

Peking Medical Research Institute No. 2023-5
6 · The paper itself

Abstract

backgroundAlthough flow diverter device (FDD) has brought revolutionized advances in endovascular treatment of intracranial aneurysms, it also presents considerable drawbacks as well, as the innovation for novel device has never stopped. This preclinical research aims to evaluate the safety and efficacy of a newly developed FDD, the EMBOPIPE, through in vivo and in vitro experiments.

methodsAneurysms were induced in 20 New Zealand white rabbits which were randomized to three follow-up groups according to the time elapsed after EMBOPIPE implantation (28, 90, and 180 days). Additional EMBOPIPEs were implanted in the abdominal aorta to cover the renal artery in nine rabbits. Angiography was performed immediately after device placement in all groups. Aneurysm occlusion, patency of renal arteries, and pathological outcomes were assessed. For the in vitro experiments, we measured the thrombogenic potential of EMBOPIPEs (n = 5) compared with bare stents (n = 5) using the Chandler loop model. Evaluation indicators were the platelet counts, macroscopic observations and scanning electron microscopy.

resultsEMBOPIPEs were successfully deployed in 19 of 20 rabbit aneurysms (95.0%). The rates of complete or near-complete aneurysm occlusion were 73.3%, 83.3%, and 100% in the 28-, 90-, and 180-day groups, respectively. All renal arteries covered by EMBOPIPEs remained patent, and the mean difference in renal artery diameter before and after the device placement in the three groups was 0.07 mm, 0.10 mm, and 0.10 mm, respectively (p = 0.77). Renal pathology was normal in all cases. The pathological findings of the aneurysms were as follows: thickened and adequate neointimal coverage at the aneurysm neck, minimal inflammatory response, near-complete smooth muscle cell layer, and endothelialization along the device. In vitro experiments showed that the platelet counts were significantly higher in EMBOPIPE blood samples than in bare stent samples and that platelet adhesion to the device was lower in the EMBOPIPE stent struts compared with bare stent struts through macroscopic observations and scanning electron microscopy.

conclusionsThe EMBOPIPE can achieve high rates of aneurysm occlusion while maintaining excellent branch artery patency. It exhibited wonderful pathological results. This novel device with phosphorylcholine surface modification could reduce platelet thrombus attached to the stent struts.

Indexed as

CoatingFlow diverterPhosphorylcholineRabbit aneurysm modelThrombogenicity

Identifiers

PMID38468329
PMCPMC10929142
OpenAlexW4392711621

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.