Evidence map›Paper›PMID 38468077›Full record

Observational studyCanadian journal of anaesthesia = Journal canadien d'anesthesie2024

Comparison of tracheal versus esophageal temperatures during laparoscopic surgery.

Eun Kyung Lee, Yu Jeong Bang, Jeayoun Kim, Hyun Joo Ahn

Open access · bronzeAbstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Canadian journal of anaesthesia = Journal canadien d'anesthesie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Eun Kyung LeeDepartment of Anesthesiology and Pain Medicine, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
Yu Jeong BangDepartment of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Jeayoun KimDepartment of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Hyun Joo AhnDepartment of Anaesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea. hyunjooahn@skku.edu.ORCID 0000-0003-1576-5308
Samsung Medical Center · KRChung-Ang University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRecently, endotracheal tubes with an embedded temperature sensor in the inner surface of the tube cuff (temperature tracheal tubes) have been developed. We sought to assess whether temperature tracheal tubes show a good agreement with esophageal temperature probes during surgery.

methodsWe enrolled 40 patients who underwent laparoscopic surgery in an observational study. The tracheas of all patients were intubated with a temperature tracheal tube, and an esophageal temperature probe was inserted into the esophagus. Tracheal and esophageal temperatures were recorded at 15-min intervals until the end of surgery. Temperatures from both devices were analyzed using Bland-Altman analysis, four-quadrant plots, and polar plots.

resultsWe analyzed 261 data points from 36 patients. Temperatures ranges were 34.2 °C to 36.6 °C for the tracheal temperature tube and 34.7 °C to 37.2 °C for the esophageal temperature probe. Bland-Altman analysis showed an acceptable agreement between the two devices, with an overall mean bias (95% limit of agreement) of -0.3 °C (-0.8 °C to 0.1 °C) and a percentage error of 3%; the trending ability (temperature changes over time) between the two devices showed a concordance rate of 94% in four-quadrant plot (cut-off ≥ 92%), but this was higher than the acceptable mean angular bias of 177° (cut-off <  ± 5°) and radial limits of agreement of 52° (cut-off <  ± 30°) in the polar plot. Bronchoscopy during extubation and patient interviews at six hours postoperatively revealed no serious injuries related to the use of the temperature tracheal tube.

conclusionThe temperature tracheal tube showed an acceptable overall mean bias of -0.3 °C and a percentage error of 3%, but incompatible trending ability with the esophageal temperature probe. STUDY REGISTRATION: cris.nih.go.kr (KCT0007265); 22 April 2022.

Indexed as

LaparoscopyTracheaBody TemperatureHumansIntubation, IntratrachealTemperatureBland–Altman analysisesophageal temperatureperioperativetracheal temperature

Identifiers

PMID38468077
OpenAlexW4392639986

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.