ArticleSurgical endoscopy2024
Enhancing endoscopic measurement: validating a quantitative method for polyp size and location estimation in upper gastrointestinal endoscopy.
Article in Surgical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAccurate measurement of polyps size is crucial in predicting malignancy, planning relevant intervention strategies and surveillance schedules. Endoscopists' visual estimations can lack precision. This study builds on our prior research, with the aim to evaluate a recently developed quantitative method to measure the polyp size and location accurately during a simulated endoscopy session.
methodsThe quantitative method merges information about endoscopic positions obtained from an electromagnetic tracking sensor, with corresponding points on the images of the segmented polyp border. This yields real-scale 3D coordinates of the border of the polyp. By utilising the sensor, positions of any anatomical landmarks are attainable, enabling the estimation of a polyp's location relative to them. To verify the method's reliability and accuracy, simulated endoscopies were conducted in pig stomachs, where polyps were artificially created and assessed in a test-retest manner. The polyp measurements were subsequently compared against clipper measurements.
resultsThe average size of the fifteen polyps evaluated was approximately 12 ± 4.3 mm, ranging from 5 to 20 mm. The test-retest reliability, measured by the Intraclass Correlation Coefficient (ICC) for polyp size estimation, demonstrated an absolute agreement of 0.991 (95% CI 0.973-0.997, p < 0.05). Bland & Altman analysis revealed a mean estimation difference of - 0.17 mm (- 2.03%) for polyp size and, a mean difference of - 0.4 mm (- 0.21%) for polyp location. Both differences were statistically non-significant (p > 0.05). When comparing the proposed method with calliper measurements, the Bland & Altman plots showed 95% of size estimation differences between - 1.4 and 1.8 mm (- 13 to 17.4%) which was not significant (p > 0.05).
conclusionsThe proposed method of measurements of polyp size and location was found to be highly accurate, offering great potential for clinical implementation to improve polyp assessment. This level of performance represents a notable improvement over visual estimation technique used in clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.