Evidence map›Paper›PMID 38466923›Full record

ArticleDento maxillo facial radiology2024

Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography.

Camila Porto Capel, Raphael Jurca Gonçalves da Motta, Ruben Pauwels, Hugo Gaêta-Araujo, Christiano Oliveira-Santos, Camila Tirapelli

Abstract read
In one paragraph

Article in Dento maxillo facial radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Camila Porto CapelDepartment of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil.ORCID 0000-0001-8573-270X
Raphael Jurca Gonçalves da MottaDepartment of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil.ORCID 0000-0002-9149-1831
Ruben PauwelsDepartment of Dentistry and Oral Health, Aarhus University, 8000 Aarhus, Denmark.ORCID 0000-0002-9462-7546
Hugo Gaêta-AraujoDepartment of Stomatology, Public Health and Forensic Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil.
Christiano Oliveira-SantosDepartment of Diagnosis & Oral Health, University of Louisville, School of Dentistry, 40202-1701, Louisville, KY, United States.ORCID 0000-0001-9936-7547
Camila TirapelliDepartment of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil.ORCID 0000-0001-5020-6515

Funding

São Paulo Research Foundation #18/22952-7
6 · The paper itself

Abstract

objectivesThis study evaluated the effect of metal artefact reduction (MAR) level and tube current on the assessment of dental implant positioning relative to the mandibular canal (MC) through cone-beam computed tomography (CBCT).

methodsTitanium dental implants were placed in dried mandibles at 0.5-mm superior to the MC (group 1/n = 8) and 0.5-mm inside the MC with perforation of the cortex (group 2/n = 10). CBCT scans were obtained with different levels of MAR (off, medium, and high) and 2 tube currents (4 and 8 mA). Four examiners analysed the images and scored the contact between the implant and the MC using a 5-point scale. Sensitivity, specificity, area under receiver operating characteristic curve (ROC), and frequency of scores were calculated. Data were compared with analysis of variance 2-way and Tukey's test and scores with Chi-square test.

resultsSpecificity and area under ROC curve decreased significantly when MAR level was high compared with MAR-medium and MAR-off. The frequency of score 3 (inconclusive) was the highest, and scores 1 and 5 (definitely no contact and definitely contact, respectively) were the lowest with MAR-high, regardless of the tube current. When MAR was off, there were higher frequencies of scores 1 and 5.

conclusionsThe level of MAR influences the assessment of the relationship between the dental implant and the MC. MAR-high led to lower diagnostic accuracy compared with MAR-medium and off. ADVANCES IN KNOWLEDGE: This article shows that high level of MAR can interfere in the diagnostic of dental implant positioning relative to the MC, decreasing its accuracy.

Indexed as

ArtifactsCone-Beam Computed TomographyDental ImplantsHumansIn Vitro TechniquesMandibleMetalsSensitivity and SpecificityTitaniumDental ImplantsMetalsTitaniumartefactscone-beam computed tomographydental implantmandibular canalmetal artefact reduction

Identifiers

PMID38466923
PMCPMC11056797

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.