Evidence map›Paper›PMID 38464494›Full record

ReviewInterventional cardiology (London, England)2024

Factors Influencing Implantation Depth During Transcatheter Aortic Valve Replacement.

Verena Veulemans, Oliver Maier, Tobias Zeus

Abstract readReview
In one paragraph

Review in Interventional cardiology (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Verena VeulemansDepartment of Cardiology, Pulmonology and Vascular Diseases, University Hospital Düsseldorf Düsseldorf, Germany.
Oliver MaierDepartment of Cardiology, Pulmonology and Vascular Diseases, University Hospital Düsseldorf Düsseldorf, Germany.
Tobias ZeusDepartment of Cardiology, Pulmonology and Vascular Diseases, University Hospital Düsseldorf Düsseldorf, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optimised implantation depth (OID) is crucial to obtain the best haemodynamic and clinical outcome during transcatheter heart valve (THV) deployment. OID ensures a better haemodynamic profile and is associated with a potential reduction in permanent pacemaker implantations, both of which are important during transcatheter aortic valve replacement (TAVR). Apart from patient-related anatomic conditions, many factors, such as THV and wire selection, as well as implantation strategies, can be controlled by the operator and facilitate the implantation process. However, there are only limited data dealing with predictors for OID. Therefore, the aim of this review was to outline factors and tools that might influence the final implantation depth during TAVR procedures, potentially influencing the outcome.

Indexed as

elderlyimplantation depthoutcomepacemakerTranscatheter aortic valve implantation

Identifiers

PMID38464494
PMCPMC10918527

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.