Decreased stress shielding with poly-ether-ether-ketone tibial implant for total knee arthroplasty - A preliminary study using finite element analysis.

Guanghui Zhao, Jing Luo, Jianbing Ma, Jianpeng Wang

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Guanghui ZhaoDepartment of Joint Surgery, Honghui Hospital, Xi'An Jiaotong University, No.555 East Youyi Road, Xi'an, Shaanxi, China.
Jing LuoDepartment of Architecture, Xi'An University of Architecture and Technology, No.13 Yanta Road, Xi'an, Shaanxi, China.
Jianbing MaDepartment of Joint Surgery, Honghui Hospital, Xi'An Jiaotong University, No.555 East Youyi Road, Xi'an, Shaanxi, China.
Jianpeng WangDepartment of Joint Surgery, Honghui Hospital, Xi'An Jiaotong University, No.555 East Youyi Road, Xi'an, Shaanxi, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In total knee arthroplasty (TKA), the mechanical mismatch between cobalt-chromium (CoCr) alloy tibial implant and bone has been implicated in stress shielding and subsequent implant failure and bone resorption. This study investigates the biomechanical advantages of poly-ether-ether-ketone (PEEK) tibial implant, which exhibit properties analogous to those of the surrounding bone. A finite element analysis (FEA) was employed to assess and compare the biomechanical performances of PEEK and CoCr tibial implants in patients with and without osteoporosis. Four FEA models were constructed with PEEK and CoCr alloy implants in normal and osteoporotic tibias. Based on previous literature and our clinical experience, stresses measurements were taken at 16 points on the tibial plateau and 8 points on the two surfaces which were 10 mm and 20 mm apart from the tibial plateau, with specific regions quantified for stress shielding. The results showed significant differences in stress distribution between PEEK and CoCr implants. The PEEK implants exhibited higher equivalent stresses on the tibial plateau in all models (normal bone: 0.22 ± 0.07 MPa vs. 0.13 ± 0.06 MPa, p < 0.01; osteoporotic bone: 0.39 ± 0.06 MPa vs. 0.17 ± 0.07 MPa, p < 0.01). In non-osteoporotic models, the mean equivalent stresses on proximal tibial surfaces were similarly elevated for PEEK implants (0.29 ± 0.13 MPa vs. 0.21 ± 0.08 MPa, p = 0.02). The CoCr implants demonstrated more stress shielding across all measured regions (tibial plateau: 23.47% vs. 2.73%; surface 1: 15.93% vs. 1.37%; surface 2: 10.71% vs. 6.56%). These disparities were even more pronounced in osteoporotic models in the CoCr group (tibial plateau: 32.50% vs. 8.36%). The maximum equivalent stresses on the tibial plateau further supported this trend (normal bone: 1.02 MPa vs. 0.52 MPa; osteoporotic bone: 1.43 MPa vs. 0.67 MPa). These data confirm the hypothesis that a PEEK tibial implant can reduce peri-prosthetic stress shielding, suggesting that PEEK implants have the capability to distribute loads more uniformly and maintain a closer approximation to physiological conditions.

Indexed as

CoCr alloyPEEKStress shieldingTibia implantTotal knee arthroplasty

Identifiers

PMID38463834
PMCPMC10920710

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.