ReviewJournal of conservative dentistry and endodontics2024
Revolutionizing endodontics: Advancements in nickel-titanium instrument surfaces.
Review in Journal of conservative dentistry and endodontics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Evaluation of different methods for separated file retrieval from the apical third of curved root canals:Journal of conservative dentistry and endodontics · 2026Article
- Effects of Sodium Hypochlorite on Corrosion Behavior and Cyclic Fatigue in Different Types of NiTi Rotary Endodontic Instruments.Materials (Basel, Switzerland) · 2026Article
- Mechanical and elemental comparison of EndoStar and One Curve nickel-titanium endodontic files: AnJournal of conservative dentistry and endodontics · 2026Article
- Review
- Cyclic Fatigue Resistance and Phase Transformation Behavior of SlimShaper and SlimShaper PRO NiTi Instruments: A Mechanical and Thermal Analysis.Dentistry journal · 2026Article
- Comparative Assessment of Observed Dentinal Defects Following Root Canal Preparation With TruNatomy, ProTaper Next, and Dia-X Nickel-Titanium Rotary Systems: An In Vitro Study.International journal of dentistry · 2026Article
- Review
- Perceptions and experiences of patients with endodontic instrument separation-a qualitative study.BMC oral health · 2025Article
- Fracture resistance and volumetric dentin change after management of broken instrument using static navigation - AnJournal of conservative dentistry and endodontics · 2025Article
- Analysis of dynamic cyclic fatigue resistance of different endodontic nickel-titanium instruments with different sterilization methods: AnJournal of conservative dentistry and endodontics · 2025Article
- Thermal behavior and cyclic fatigue resistance of three contemporary NiTi heat-treated single-file systems: metallurgical study.BMC oral health · 2025Article
- Root canal instrumentation of artificial primary teeth with rotary and reciprocating files: a micro-CT analysis.Brazilian oral research · 2025Article
- A Comparative Study of Temperature Variations in Incisor Root Surfaces During Root Canal Preparation Using Various Rotary Systems and Irrigation Protocols.Journal of clinical medicine · 2024Article
- Cyclic Fatigue Resistance of Four Heat-Treated Nickel-Titanium Files in Severely Curved Simulated Canals: An In Vitro Study.Journal of clinical medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Nickel-titanium (NiTi) instruments have become the backbone of endodontics due to their exceptional properties, superelasticity, and shape memory. However, challenges such as unexpected breakage, poor cutting efficiency, and corrosion have prompted researchers to explore innovative surface modifications to enhance their performance. This comprehensive review discusses the latest advancements in NiTi metallurgy and their impact on rotary NiTi file systems. Various surface treatment techniques, including ion implantation, cryogenic treatment (CT), thermal nitridation, electropolishing, and physical or chemical vapor deposition, have been investigated to minimize defects, boost surface hardness, and improve cyclic fatigue resistance. Ion implantation has shown promise by increasing wear resistance and cutting efficiency through nitrogen ion incorporation. Thermal nitridation has successfully formed titanium nitride (TiN) coatings, resulting in improved corrosion resistance and cutting efficiency. CT has demonstrated increased cutting efficiency and overall strength by creating a martensite transformation and finer carbide particles. Electropolishing has yielded mixed results, providing smoother surfaces but varying impacts on fatigue resistance. Physical or chemical vapor deposition has proven effective in forming TiN coatings, enhancing hardness and wear resistance. Furthermore, the concept of surface functionalization with silver ions for antibacterial properties has been explored. These advancements present an exciting future for endodontic procedures, offering the potential for enhanced NiTi instruments with improved performance, durability, and patient outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.