ArticlePractical laboratory medicine2024

Detection of infliximab, adalimumab, and anti-drug antibodies: Development and validation of new monotest, automated assays on multiparametric instrument.

Helena Cerutti, Giulia Tesi, Francesco Petrini, Tommaso Bandini, Alessandra Cartocci, Andrea Ianniello, Alessia Bogi, Chiara Muzzi, Alessandra Brogi

Abstract read
In one paragraph

Article in Practical laboratory medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Helena CeruttiDIESSE Diagnostica Senese S.p.A. Società Benefit: Strada dei Laghi 35-39, Monteriggioni, Siena, Italy.
Giulia TesiDIESSE Diagnostica Senese S.p.A. Società Benefit: Strada dei Laghi 35-39, Monteriggioni, Siena, Italy.
Francesco PetriniDIESSE Diagnostica Senese S.p.A. Società Benefit: Strada dei Laghi 35-39, Monteriggioni, Siena, Italy.
Tommaso BandiniDIESSE Diagnostica Senese S.p.A. Società Benefit: Strada dei Laghi 35-39, Monteriggioni, Siena, Italy.
Alessandra CartocciDipartimento di Biotecnologie Mediche, Università di Siena, Siena, Italy.
Andrea IannielloDIESSE Diagnostica Senese S.p.A. Società Benefit: Strada dei Laghi 35-39, Monteriggioni, Siena, Italy.
Alessia BogiDIESSE Diagnostica Senese S.p.A. Società Benefit: Strada dei Laghi 35-39, Monteriggioni, Siena, Italy.
Chiara MuzziDIESSE Diagnostica Senese S.p.A. Società Benefit: Strada dei Laghi 35-39, Monteriggioni, Siena, Italy.
Alessandra BrogiDIESSE Diagnostica Senese S.p.A. Società Benefit: Strada dei Laghi 35-39, Monteriggioni, Siena, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To convert manual ELISA kits to fully automated immunoassays that quantify serum drug levels and anti-drug antibodies levels of infliximab and adalimumab (CHORUS Promonitor kits). Desing and methods: CHORUS Promonitor INFLIXIMAB, CHORUS Promonitor ADALIMUMAB, CHORUS Promonitor ANTI-INFLIXIMAB, and CHORUS Promonitor ANTI-ADALIMUMAB kits were compared with the corresponding Promonitor kits to determine sensitivity and specificity of the assays. For the automated assays, the entire procedure -from samples dilution to final readouts-was performed by CHORUS TRIO instrument (DIESSE, Italy). Residual human serum samples from clinical laboratory investigations and samples resulting from the addition of specific drugs (IFX or ADL) or anti-drug antibodies (anti-IFX or anti-ADL) were used for the characterization and validation of the tests. Results: CHORUS Promonitor kits showed an excellent agreement (Cohen's coefficient = 1) with the Promonitor kits and were linear within predefined ranges. All assays were accurate and repeatable, as an acceptable variability were observed within runs, between runs, lots, and instruments. No difference in detecting the reference drug or biosimilars emerged. Conclusion: During preclinical development, these kits resulted as sensitive, specific, accurate, and able to quantify either the reference drug or the corresponding biosimilars. All these features support their use in clinical practice for therapeutic drug monitoring of patients with inflammatory diseases under treatment with IFX or ADL.

Indexed as

Anti-drug antibodyELISAInflammatory diseaseTherapeutic drug monitoring

Identifiers

PMID38463198
PMCPMC10924048

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.