Evidence map›Paper›PMID 38459802›Full record

ArticleOrthodontics & craniofacial research2024

Effect of attachment configuration and trim line design on the force system of orthodontic aligners: A finite element study on the upper central incisor.

Tarek M Elshazly, Christoph Bourauel, Mostafa Aldesoki, Damiano Salvatori, Abdulaziz Alhotan, Ludger Keilig, Ahmed Ghoneima

Abstract read
In one paragraph

Article in Orthodontics & craniofacial research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tarek M ElshazlyOral Technology, Dental School, University Hospital Bonn, Bonn, Germany.ORCID https://orcid.org/0000-0002-3219-9048
Christoph BourauelOral Technology, Dental School, University Hospital Bonn, Bonn, Germany.ORCID https://orcid.org/0000-0002-2195-1011
Mostafa AldesokiOral Technology, Dental School, University Hospital Bonn, Bonn, Germany.ORCID https://orcid.org/0000-0002-3799-0496
Damiano SalvatoriInstitut Straumann AG, Basel, Switzerland.
Abdulaziz AlhotanDepartment of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
Ludger KeiligOral Technology, Dental School, University Hospital Bonn, Bonn, Germany.
Ahmed GhoneimaDepartment of Orthodontics and Pediatric Dentistry, Hamdan Bin Mohammed College of Dental Medicine (HBMCDM), Mohammed Bin Rashid University of Medicine and Health Sciences (MBRU), Dubai, United Arab Emirates.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo use the finite element method (FEM) to investigate the effect of various attachment configurations and trimming line designs of orthodontic aligners on their biomechanical performance.

methodA 3D upper jaw model was imported into 3D design software. The upper right central incisor tooth (Tooth 11) was made mobile, and its periodontal ligament (PDL) and bone structures were designed. Aligners were modelled with three distinct attachment configurations: No attachment, rectangular horizontal, rectangular vertical, and two trimming line designs; scalloped and straight extended, with a homogeneous thickness of 0.6 mm. These models were then imported into an FE software. Simulations were conducted for three different movements, including facial translation, distalization, and extrusion.

resultsForces were recorded at 1.3-2.6 N during facial translation, 1.4-5.9 N in distalization, and 0.0-2.0 N in extrusion. The straight extended trimming line consistently generated higher forces than the scalloped design. Attachments had no significant impact on force components during facial translation but were more effective in distalization and extrusion. The combination of a straight extended trimming line with horizontal attachments exhibited the least stresses at the apical third during distalization, and the highest stresses during extrusion, suggesting superior retention.

conclusionsRectangular attachments offer limited benefits in facial translation, but horizontal rectangular attachments can intensify load in distalization and are crucial for force generation in extrusion. Horizontal attachments are preferred over vertical options. Additionally, the straight extended trim line enhances control of tooth movement and can replace attachments in certain cases. CLINICAL RELEVANCE: These findings provide biomechanical evidence and an optimal protocol to guide clinical practice in planning diverse teeth movements. The emphasis is on the influence of attachment utilization and the specific design of aligner trimming lines to enhance control over tooth movement.

Indexed as

Finite Element AnalysisIncisorTooth Movement TechniquesBiomechanical PhenomenaComputer SimulationDental Stress AnalysisHumansMaxillaOrthodontic Appliance DesignPeriodontal LigamentStress, Mechanicalbiomechanicsorthodontic forceremovable thermoplastic appliancestress analysistooth movement

Identifiers

PMID38459802
PMCPMC11654353

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.