Evidence map›Paper›PMID 38459346›Full record

ArticleEuropean radiology2024

Altered probe pressure and body position increase diagnostic accuracy for men and women in detecting hepatic steatosis using quantitative ultrasound.

Marie Byenfeldt, Johan Kihlberg, Patrik Nasr, Christer Grönlund, Anna Lindam, Wolf C Bartholomä, Peter Lundberg, Mattias Ekstedt

Open access · hybridAbstract read
In one paragraph

Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
4.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Marie Byenfeldt *Department of Radiology in Östersund, Östersund, Sweden. marie.byenfeldt@umu.se.ORCID http://orcid.org/0000-0001-9338-1639
Johan Kihlberg *Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Patrik Nasr *Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
Christer Grönlund *Department of Radiation Science, Umeå University, Umeå, Sweden.
Anna Lindam *Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden.
Wolf C Bartholomä *Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Peter Lundberg *Department of Radiation Physics, Linköping University, Linköping, Sweden.
Mattias Ekstedt *Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
Linköping University · SEUmeå University · SE

Funding

Cancer Research Foundation in Northern Sweden LP 20-2221Forskningsrådet i Sydöstra Sverige 752871
6 · The paper itself

Abstract

objectivesTo evaluate the diagnostic performance of ultrasound guided attenuation parameter (UGAP) for evaluating liver fat content with different probe forces and body positions, in relation to sex, and compared with proton density fat fraction (PDFF).

methodsWe prospectively enrolled a metabolic dysfunction-associated steatotic liver disease (MASLD) cohort that underwent UGAP and PDFF in the autumn of 2022. Mean UGAP values were obtained in supine and 30° left decubitus body position with normal 4 N and increased 30 N probe force. The diagnostic performance was evaluated by the area under the receiver operating characteristic curve (AUC).

resultsAmong 60 individuals (mean age 52.9 years, SD 12.9; 30 men), we found the best diagnostic performance with increased probe force in 30° left decubitus position (AUC 0.90; 95% CI 0.82-0.98) with a cut-off of 0.58 dB/cm/MHz. For men, the best performance was in supine (AUC 0.91; 95% CI 0.81-1.00) with a cut-off of 0.60 dB/cm/MHz, and for women, 30° left decubitus position (AUC 0.93; 95% CI 0.83-1.00), with a cut-off 0.56 dB/cm/MHz, and increased 30 N probe force for both genders. No difference was in the mean UGAP value when altering body position. UGAP showed good to excellent intra-reproducibility (Intra-class correlation 0.872; 95% CI 0.794-0.921).

conclusionUGAP provides excellent diagnostic performance to detect liver fat content in metabolic dysfunction-associated steatotic liver diseases, with good to excellent intra-reproducibility. Regardless of sex, the highest diagnostic accuracy is achieved with increased probe force with men in supine and women in 30° left decubitus position, yielding different cut-offs. CLINICAL RELEVANCE STATEMENT: The ultrasound method ultrasound-guided attenuation parameter shows excellent diagnostic accuracy and performs with good to excellent reproducibility. There is a possibility to alter body position and increase probe pressure, and different performances for men and women should be considered for the highest accuracy. KEY POINTS: • There is a possibility to alter body position when performing the ultrasound method ultrasound-guided attenuation parameter. • Increase probe pressure for the highest accuracy. • Different performances for men and women should be considered.

Indexed as

UltrasonographyAdultAgedFatty LiverFemaleHumansLiverMaleMiddle AgedPatient PositioningPressureProspective StudiesReproducibility of ResultsSex FactorsFatty liverMagnetic resonance imagingPatient positioningSex factorsUltrasonography

Identifiers

PMID38459346
PMCPMC11364715
OpenAlexW4392583198

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.