Evidence map›Paper›PMID 38459202›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2024

Impact of infective versus sterile transvenous lead removal on 30-day outcomes in cardiac implantable electronic devices.

Fahimeh Talaei, Qi-Xuan Ang, Min-Choon Tan, Mustafa Hassan, Luis Scott, Yong-Mei Cha, Justin Z Lee, Kamala Tamirisa

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 95% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 8 institutions in 1 country.

Fahimeh TalaeiDepartment of Cardiovascular Medicine, Mayo Clinic, Phoenix, AZ, USA.
Qi-Xuan AngDepartment of Internal Medicine, Sparrow Health System and Michigan State University, East Lansing, MI, USA.
Min-Choon TanDepartment of Internal Medicine, New York Medical College at Saint Michael's Medical Center, Newark, NJ, USA.
Mustafa HassanDepartment of Cardiovascular Medicine, McLaren Health System and Michigan State University, Flint, MI, USA.
Luis ScottDepartment of Cardiovascular Medicine, Mayo Clinic, Phoenix, AZ, USA.
Yong-Mei ChaDepartment of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
Justin Z LeeDepartment of Cardiovascular Medicine, Mayo Clinic, Phoenix, AZ, USA.
Kamala TamirisaTexas Cardiac Arrhythmia Institute, Austin and Dallas, TX, USA. tamirisakamala@gmail.com.
Cleveland Clinic · USMayo Clinic in Arizona · USMayo Clinic in Florida · USMcLaren Health Care · USMichigan State University · USSaint Michael's Medical Center · USTexas Cardiac Arrhythmia · USWinnMed · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTransvenous lead removal (TLR) is associated with increased mortality and morbidity. This study sought to evaluate the impact of TLR on in-hospital mortality and outcomes in patients with and without CIED infection.

methodsFrom January 1, 2017, to December 31, 2020, we utilized the nationally representative, all-payer, Nationwide Readmissions Database to assess patients who underwent TLR. We categorized TLR as indicated for infection, if the patient had a diagnosis of bacteremia, sepsis, or endocarditis during the initial admission. Conversely, if none of these conditions were present, TLR was considered sterile. The impact of infective vs sterile indications of TLR on mortality and major adverse events was studied.

resultsOut of the total 25,144 patients who underwent TLR, 14,030 (55.8%) received TLR based on sterile indications, while 11,114 (44.2%) received TLR due to device infection, with 40.5% having systemic infection and 59.5% having isolated pocket infection. TLR due to infective indications was associated with a significant in-hospital mortality (5.59% vs 1.13%; OR = 5.16; 95% CI 4.33-6.16; p < 0.001). Moreover, when compared with sterile indications, TLR performed due to device infection was associated with a considerable risk of thromboembolic events including pulmonary embolism and stroke (OR = 3.80; 95% CI 3.23-4.47, p < 0.001). However, there was no significant difference in the conversion to open heart surgery (1.72% vs. 1.47%, p < 0.111), and infection was not an independent predictor of cardiac (OR = 1.12; 95% CI 0.97-1.29) or vascular complications (OR = 1.12; 95% CI 0.73-1.72) between the two groups.

conclusionHigher in-hospital mortality and rates of thromboembolic events associated with TLR resulting from infective indications may warrant further pursuing this diagnosis in patients.

Indexed as

Defibrillators, ImplantableDevice RemovalHospital MortalityPacemaker, ArtificialProsthesis-Related InfectionsAgedFemaleHumansMaleMiddle AgedRetrospective StudiesUnited StatesCardiac implantable electronic devicesDevice infectionSterile lead extractionTransvenous lead extraction

Identifiers

PMID38459202
OpenAlexW4392624700

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.