Evidence map›Paper›PMID 38456473›Full record

ArticleJournal of the American Heart Association2024

Patient Screening for Self-Expanding Percutaneous Pulmonary Valves Using Virtual Reality.

Jenny E Zablah, Jeannie Than, Lorna P Browne, Salvador Rodriguez, Gareth J Morgan

Open access · goldAbstract read
In one paragraph

Article in Journal of the American Heart Association, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. One Anatomy, Multiple Valve Choices: Interobserver Agreement in Selecting Transcatheter Pulmonary Valve.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jenny E ZablahDepartment of Pediatrics, University of Colorado Anschutz Medical Campus Heart Institute, Children's Hospital Colorado Aurora CO.ORCID 0000-0002-9146-8551
Jeannie ThanModern Human Anatomy School University of Colorado Anschutz Medical Campus Aurora CO.
Lorna P BrowneDepartment of Radiology University of Colorado Anschutz Medical Campus Aurora CO.ORCID 0000-0002-8080-5276
Salvador RodriguezDepartment of Pediatrics, University of Colorado Anschutz Medical Campus Heart Institute, Children's Hospital Colorado Aurora CO.ORCID 0000-0001-9786-3651
Gareth J MorganDepartment of Pediatrics, University of Colorado Anschutz Medical Campus Heart Institute, Children's Hospital Colorado Aurora CO.ORCID 0000-0003-1500-9334
Children's Hospital Colorado · USUniversity of Colorado Anschutz Medical Campus · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn recent years, self-expanding technology to treat pulmonary regurgitation in the native right ventricular outflow tract became Food and Drug Administration approved in the United States and is now routinely used. The current practice for selection of patients who are candidates for these devices includes screening for "anatomic fit," performed by each of the manufacturing companies. Our study aims to validate the use of virtual reality (VR) as a tool for local physician-led screening of patients. METHODS AND

resultsThis retrospective study from Children's Hospital Colorado included patients who underwent pulmonary valve replacement and had screening for a Harmony TPV or Alterra Prestent performed between September 2020 and January 2022. The data from the commercial companies' dedicated analysis for self-expanding transcatheter pulmonary valve frames evaluation with perimeter analysis were collected. VR simulation was performed blinded by 2 congenital interventional cardiologists using Elucis VR software and an Oculus Quest 2 headset. Among the 27 evaluated cases, the use of a self-expandable valve was recommended by companies' dedicated analysis in 23 cases (85.2%), by VR assessment in 26 cases (96.3), and finally implanted in 25 cases (92.6%). Regarding the level of agreement, both modalities (manufacturer and VR) were good at screening-in patients who received a self-expanding valve (100% versus 96.1%). When it came to screening-out the patients, VR presented good capacity to accurately classify nonsuitable patients (50% versus 100%).

conclusionsOur institutional experience with VR transcatheter pulmonary valve implantation planning accurately predicted clinical outcomes. This paves the way for routine use of VR in patient selection for self-expanding valve technologies.

Indexed as

Heart Valve ProsthesisHeart Valve Prosthesis ImplantationPulmonary ValveVirtual RealityCardiac CatheterizationChildHumansProsthesis DesignRetrospective StudiesTreatment OutcomeUnited StatesAlterra Prestentanatomic fitharmony TPVself‐expanding technologytranscatheter pulmonary valve implantationvirtual reality

Identifiers

PMID38456473
PMCPMC11009987
OpenAlexW4392596928

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.